MOSEL VITELIC
AC Characteristics
(Cont’d)
50
#
Symbol
Parameter
Min.
V53C16258SH
Max.
Unit
Notes
Self Refresh
57
t
RASS
t
RPS
t
CHS
t
CHD
RAS Pulse Width During Self
Refresh
RAS Precharge Time During
Self Refresh
CAS Hold Time Width During
Self Refresh
CAS Low Time During Self
Refresh
100
ms
ns
18
58
100
18
59
100
ns
ms
18
60
100
18
Notes:
1. I
CC
is dependent on output loading when the device output is selected. Specified I
CC
(max.) is measured with the
output open.
2. I
CC
is dependent upon the number of address transitions. Specified I
CC
(max.) is measured with a maximum of two
transitions per address cycle in EDO Page Mode.
3. Specified V
IL
(min.) is steady state operating. During transitions, V
IL
(min.) may undershoot to –1.0 V for a period
not to exceed 20 ns. All AC parameters are measured with V
IL
(min.)
³
V
SS
and V
IH
(max.)
£
V
CC
.
4. t
RCD
(max.) is specified for reference only. Operation within t
RCD
(max.) limits insures that t
RAC
(max.) and t
CAA
(max.) can be met. If t
RCD
is greater than the specified t
RCD
(max.), the access time is controlled by t
CAA
and t
CAC
.
5. Either t
RRH
or t
RCH
must be satisified for a Read Cycle to occur.
6. Measured with a load equivalent to one TTL input and 50 pF.
7. Access time is determined by the longest of t
CAA
, t
CAC
and t
CAP
.
8. Assumes that t
RAD
£
t
RAD
(max.). If t
RAD
is greater than t
RAD
(max.), t
RAC
will increase by the amount that t
RAD
exceeds t
RAD
(max.).
9. Assumes that t
RCD
£
t
RCD
(max.). If t
RCD
is greater than t
RCD
(max.), t
RAC
will increase by the amount that t
RCD
exceeds t
RCD
(max.).
10. Assumes that t
RAD
³
t
RAD
(max.).
11. Operation within the t
RAD
(max.) limit ensures that t
RAC
(max.) can be met. t
RAD
(max.) is specified as a reference
point only. If t
RAD
is greater than the specified t
RAD
(max.) limit, the access time is controlled by t
CAA
and t
CAC
.
12. t
WCS
, t
RWD
, t
AWD
and t
CWD
are not restrictive operating parameters.
13. t
WCS
(min.) must be satisfied in an Early Write Cycle.
14. t
DS
and t
DH
are referenced to the latter occurrence of CAS or WE.
15. t
T
is measured between V
IH
(min.) and V
IL
(max.). AC-measurements assume t
T
= 3 ns.
16. Assumes a three-state test load (5 pF and a 500 Ohm Thevenin equivalent).
17. An initial 200
ms
pause and 8 RAS-containing cycles are required when exiting an extended period of bias without
clocks. An extended period of time without clocks is defined as one that exceeds the specified Refresh Interval.
18. One CBR refresh or complete set of row refresh cycles must be completed upon existing Self Refresh Mode.
V53C16258SH Rev 0.2 Aug. 1998