MO SEL VITELIC  
V53C16126H  
Notes:  
1. ICC is dependent on output loading when the device output is selected. Specified ICC (max.) is measured with the  
output open.  
2.  
ICC is dependent upon the number of address transitions. Specified ICC (max.) is measured with a maximum of two  
transitions per address cycle in Fast Page Mode.  
3. Specified VIL (min.) is steady state operating. During transitions, VIL (min.) may undershoot to –1.0 V for a period  
not to exceed 20 ns. All AC parameters are measured with VIL (min.) VSS and VIH (max.) VCC  
.
4. tRCD (max.) is specified for reference only. Operation within tRCD (max.) limits insures that tRAC (max.) and tCAA  
(max.) can be met. If tRCD is greater than the specified tRCD (max.), the access time is controlled by tCAA and tCAC  
.
5. Either tRRH or tRCH must be satisified for a Read Cycle to occur.  
6. Measured with a load equivalent to one TTL input and 100 pF.  
7. Access time is determined by the longest of tCAA, tCAC and tCAP  
.
8. Assumes that tRAD tRAD (max.). If tRAD is greater than tRAD (max.), tRAC will increase by the amount that tRAD ex-  
ceeds tRAD (max.).  
9. Assumes that tRCD tRCD (max.). If tRCD is greater than tRCD (max.), tRAC will increase by the amount that tRCD ex-  
ceeds tRCD (max.).  
10. Assumes that tRAD tRAD (max.).  
11. Operation within the tRAD (max.) limit ensures that tRAC (max.) can be met. tRAD (max.) is specified as a reference  
point only. If tRAD is greater than the specified tRAD (max.) limit, the access time is controlled by tCAA and tCAC  
.
12.  
13.  
14.  
t
t
t
WCS, tRWD, tAWD and tCWD are not restrictive operating parameters.  
WCS (min.) must be satisfied in an Early Write Cycle.  
DS and tDH are referenced to the latter occurrence of CAS or WE.  
15. tT is measured between VIH (min.) and VIL (max.). AC-measurements assume tT = 3 ns.  
16. Assumes a three-state test load (5 pF and a 380 Ohm Thevenin equivalent).  
17. An initial 200 µs pause and 8 RAS-containing cycles are required when exiting an extended period of bias without  
clocks. An extended period of time without clocks is defined as one that exceeds the specified Refresh Interval.  
V53C16126H Rev. 1.3 February 1998  
7