MOSEL VITELIC
T
A
= 0
°
C to 70
°
C; V
SS
= 0 V; V
DD
, V
DDQ
= 3.3V
±
0.3V
V43658Y04VATG-75PC
DC Characteristics
Limit Values
Symbol
V
IH
V
IL
V
OH
V
OL
I
I(L)
I
O(L)
Parameter
Input High Voltage
Input Low Voltage
Output High Voltage (I
OUT
= –2.0 mA)
Output Low Voltage (I
OUT
= 2.0 mA)
Input Leakage Current, any input
(0 V < V
IN
< 3.6 V, all other inputs = 0V)
Output leakage current
(DQ is disabled, 0V < V
OUT
< V
CC
)
Min.
2.0
–0.5
2.4
—
–10
Max.
V
CC
+0.3
0.8
—
0.4
10
Unit
V
V
V
V
µ
A
µ
A
–10
10
T
A
= 0
°
C to 70
°
C; V
DD
= 3.3V
±
0.3V, f = 1 MHz
Symbol
C
I1
C
I2
C
ICL
C
I3
C
I4
C
SC
C
IO
Capacitance
Parameter
Input Capacitance (A0 to A11, RAS, CAS, WE)
Input Capacitance (CS0, CSI)
Input Capacitance (CLK0-CLK1)
Input Capacitance (CKE0, CKEI)
Input Capacitance (DQMB0-DQMB7)
Input Capacitance (SCL, SA0-2)
Input/Output Capacitance
Limit Values
105
32
40
65
20
8
10
Unit
pF
pF
pF
pF
pF
pF
pF
Standby and Refresh Currents
1
T
A
= 0
°
C to 70
°
C, V
CC
= 3.3V
±
0.3V
Symbol Parameter
I
CC
1
I
CC
2P
I
CC
2N
Operating Current
Test Conditions
Burst length = 4, CL = 3
t
RC
> = t
RC
(min), t
CK
> = t
CK
(min)
CKE< = V
IL
(max), t
CK
> = t
CK
(min)
CKE> = V
IH
(min), t
CK
> = t
CK
(min), Input
changed once in 3 cycles
8M x 64
680
Unit
mA
Note
1,2
Precharged Standby Current in Power
Down Mode
Precharged Standby Current in
Non-Power Down Mode
6
mA
180
mA
CS =
High
I
CC
3P
I
CC
3N
I
CC
4
I
CC
5
I
CC
6
Active Standby Current in Power
Down Mode
Active Standby Current in Non-Power
Down Mode
Burst Operating Current
Auto Refresh Current
Self Refresh Current
CKE< = V
IL
(max), t
CK
> = t
CK
(min)
CKE> = V
IH
(min), t
CK
> = t
CK
(min), Input
changed one time
t
RC
= Infinite, CL = 3, t
CK
> = t
CK
(min)
t
RC
>= t
RC
(min)
CKE = <0,2 V
L-Version
40
mA
220
mA
CS =
High
1, 2
1,2
1,2
440
1000
6
3.2
mA
mA
mA
mA
V43658Y04VATG-75PC Rev. 1.0 July 2001
6