MOSEL VITELIC
AC Electrical Characteristics
(over all temperature ranges)
Read Cycle
Parameter
Name
t
RC
t
AA
t
ACS
t
OE
t
CLZ
t
OLZ
t
DF
t
OH
V29C51000T/V29C51000B
-45
Parameter
Read Cycle Time
Address Access Time
Chip Enable Access Time
Output Enable Access Time
CE Low to Output Active
OE Low to Output Active
Output Enable or Chip Disable to Output in
High Z
Output Hold from Address Change
-70
Max.
—
45
45
25
—
—
20
-90
Max.
—
70
70
35
—
—
20
Min.
45
—
—
—
0
0
0
Min.
70
—
—
—
0
0
0
Min.
90
—
—
—
0
0
0
Max.
—
90
90
45
—
—
30
Unit
ns
ns
ns
ns
ns
ns
ns
0
—
0
—
0
—
ns
Program (Erase/Program) Cycle
Parameter
Name
t
WC
t
AS
t
AH
t
CS
t
CH
t
OES
t
OEH
t
WP
t
WPH
t
DS
t
DH
t
WHWH1
t
WHWH2
t
WHWH3
-45
Parameter
Program Cycle Time
Address Setup Time
Address Hold Time
CE Setup Time
CE Hold Time
OE Setup Time
OE High Hold Time
WE Pulse Width
WE Pulse Width High
Data Setup Time
Data Hold Time
Programming Cycle
Sector Erase Cycle
Chip Erase Cycle
-70
-90
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit
45
0
35
0
0
0
0
25
20
20
0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
500
—
—
—
—
—
—
—
—
—
—
—
20
10
—
70
0
45
0
0
0
0
35
35
25
0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
500
—
—
—
—
—
—
—
—
—
—
—
20
10
—
90
0
45
0
0
0
0
45
38
30
0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
500
—
—
—
—
—
—
—
—
—
—
—
20
10
—
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
µs
ms
ms
V29C51000T/V29C51000B Rev. 0.5 October 2000
5