MO SEL VITELIC
V29C51000T/V29C51000B
Boot Block Detection
Manufacturer ID
In Autoselect mode, performing a read at
address 3CXX2H or address 0CXX2H will indicate
if the Top Boot Block sector or the Bottom Boot
Block sector is locked out. If the data is 01H, the
Top/Bottom Boot Block is protected. If the data is
00H, the Top/Bottom Boot Block is unprotected.
(see Table 3.)
In Autoselect mode, performing a read at
address. XXXX0H will determine the manufacturer
ID. 40H is the manufacturer code for Mosel Vitelic
Flash.
In addition the manufacturer ID can also be read
via the command register when the device is
erased or programmed in a system without
applying high voltage to the A pin. when A is
LOW, the manufacturer ID is presented at the
outputs.
9
0
Device ID
In Autoselect mode, performing a read at
address XXXXH will determine whether the device
is a Top Boot Block device or a Bottom Boot Block
device. If the data is 00H, the device is a Top Boot
Block. If the data is A0H, the device is a Bottom
Boot Block device (see Table 3).
In addition, the device ID can also be read via the
command register when the device is erased or
programmed in a system without applying high
Hardware Data Protection
V
Sense Protection: the program operation is
CC
inhibited when VCC is less than 2.5V.
Noise Protection: a CE or WE pulse of less than
5ns will not initiate a program cycle.
Program Inhibit Protection: holding any one of
OE LOW, CE HIGH or WE HIGH inhibits a program
cycle.
voltage to the A pin. When A is HIGH, the device
9
0
ID is presented at the outputs.
Table 3. Autoselect Decoding
Address
Decoding Mode
Boot Block
A
A
A –A
A
–A
Data I/O –I/O
0
IL
IL
IH
1
IH
IH
2
13
14
17
0
7
Boot Block Protection
Top
V
V
V
V
X
X
X
V
01H: protected
IH
Bottom
Top
V
00H: unprotected
IL
Device ID
V
V
X
01H
00H
A0H
IL
Bottom
Manufacture ID
V
V
X
X
IL
IL
NOTE:
1. X = Don’t Care, V = HIGH, V = LOW.
IH
IL
V29C51000T/V29C51000B Rev. 0.5 October 2000
11