ISSUE 4.3 : November 1998
PUMA 68F16006/A-80/90/12/15
Version 'A' Pin Definition
Version 'A' Block Diagram
A0~A18
64 63 62 61
8 7 6 5 4 3 2 1 68 67 66 65
9
10
D1 11
D0
60
D16
D17
D18
D19
D20
D21
D22
D23
GND
D24
D25
D26
D27
D28
D29
D30
D31
OE
WE4
WE3
WE2
WE1
59
58
57
56
55
54
53
52
51
50
49
48
47
46
45
44
12
13
14
15
16
17
D2
D3
D4
D5
D6
D7
PUMA 68F16006A
VIEW
FROM
ABOVE
512K x 8
FLASH
512K x 8
FLASH
512K x 8
FLASH
512K x 8
FLASH
GND 18
19
20
21
22
23
24
25
26
D8
D9
D10
D11
D12
D13
D14
D15
CS1
CS2
CS3
CS4
D0~7
27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43
D8~15
D16~23
D24~31
SCREENING
Military Screening Procedure
Screening Flow for high reliability product is in accordance with Mil-883 method 5004 .
MB MODULE SCREENING FLOW
SCREEN
TEST METHOD
LEVEL
Visual and Mechanical
Temperature cycle
1010 Condition B (10 Cycles,-55oC to +125oC)
100%
Burn-In
Pre-Burn-in electrical
Burn-in
Per applicable device specifications at TA=+25oC
TA=+125oC,160hrs minimum.
100%
100%
Final Electrical Tests
Per applicable Device Specification
Static (DC)
a) @ TA=+25oC and power supply extremes
b) @ temperature and power supply extremes
100%
100%
Functional
a) @ TA=+25oC and power supply extremes
b) @ temperature and power supply extremes
100%
100%
Switching (AC)
a) @ TA=+25oC and power supply extremes
b) @ temperature and power supply extremes
100%
100%
External Visual
2009 Per vendor or customer specification
100%
24