PARALLEL LINES MEASURE
Copper sheet
Fuse
C1
C2
Load
2
Oscillograph
25.4mm
25.4mm
C1:10μF
C2:0.1μF
TYPICAL APPLICATIONS
LB**-10B**( single Output)
LB**-10A**(Dual output)
Fuse
Fuse
NTC
NTC
C1 C2 TVS1 RL
C1 C2 TVS1 RL
L
L
L
+Vo
L
+Vo
-Vo
N
N
Com
N
N
-Vo
C3
C4
RL
TVS2
LB**-10D**(Isolate Twin Output)
Fuse NTC
C1 C2 TVS1 RL
+
Vo1
-
L
L
N
N
+
Vo2
-
C3 C4 TVS2 RL
EXTERNAL TYPICAL VALUE
MODEL
LB03-10B03
LB03-10B05
LB03-10B12
LB03-10B15
LB03-10B24
LB05-10B03
LB05-10B05
LB05-10B09
LB05-10B12
LB05-10B15
LB05-10B24
LB05-10A05
LB05-10A12
LB05-10A15
LB05-10A24
LB05-10D0505-01
LB05-10D0512-01
LB05-10D0515-01
C1(uF)
220
220
120
68
C3(uF)
MODEL
LB10-10B03
LB10-10B05
LB10-10B09
LB10-10B12
LB10-10B15
LB10-10B24
LB10-10A05
LB10-10A12
LB10-10A15
LB10-10D0505-02I
LB15-10B03
LB15-10B05
LB15-10B12
LB15-10B15
LB15-10B24
C1(uF)
470
330
120
120
120
68
C3(uF)
10
330
330
120
120
68
220
120
47
220
120
47
220
330
680
220
220
68
120
68
120
68
120
68
47
10
68
68
47
47
47
10
220
220
220
220
LB05-10D0524-01
Remark:
1. Output filtering capacitor C3 and C1 are electrolytic capacitor. It is recommended to use high frequency and low resistance electrolytic capacitor. For capacitance
and current of the capacitor please refer to suppliers’ specifications. Voltage derating of capacitor should be 80% or above. C2, C4 and C6 eliminate high
frequency noise. TVS is a recommended component to protect post-circuits (when converter fails).
2. External input NTC is recommended to use 5D-9 ( Only LB10 models)
The copyright and authority for the interpretation of the products are reserved by Mornsun
Specifications subject to change without notice.
LB** A/1-2008 Page 3 of 4