OUTLINE DIMENSIONS & PIN CONNECTIONS
F_M-1W
MECHANICAL DIMENSIONS
RECOMMENDED FOOTPRINT
(Front View)
1
2
3
4
0.50
[0.020]
0.50[0.020]
[0.453]
11.50
7.62
[0.300]
∅1.00[0.039]
Note:grid 2.54*2.54mm.
TUBE OUTLINE DIMENSIONS
1
2
3
4
(Bottom View)
9.60
[0.378]
FOOTPRINT DETAILS
Pin
1
Function
GND
Vin
2
Note:
Unit :mm[inch]
4.90 [0.193]
3
0V
General tolerances±: 0.50mm±[ 0.020inch]
L=530mm[20.866inch] Tube Quantity: 43pcs
L=220mm[8.661inch] Tube Quantity: 17pcs
4
+Vo
Short tube inner package dimensions: L*W*H= 255*170*80mm
Short tube outer package dimensions(with six inner package boxes):
L*W*H= 375*280*270mm
Note
Unit mm[inch]
Pin section tolerances ±0.10mm[±0.004inch]
:
:
:
Long tube inner package dimensions: L*W*H= 580*200*100mm
Long tube outer package dimensions(with two inner package boxes):
L*W*H= 600*215*220mm
General tolerances:±0.25mm[±0.010inch]
Long tube outer package dimensions(with three inner package boxes)
L*W*H= 600*215*325mm
F_N-1W
MECHANICAL DIMENSIONS
RECOMMENDED FOOTPRINT
(Front View)
7
5
4
1
4.10 [0.161]
5.08[0.200]
∅1.00 [0.039]
Note:grid:2.54*2.54 mm.
12.70[0.500]
7.62[0.300]
TUBE OUTLINE DIMENSIONS
1
4
12.50[0.492]
(Bottom View)
7
5
0.50[0.020]
F OO T PRINT DETAILS
Pin
1
F unction
GND
3.50[0.138]
Note:
Unit :mm[inch]
Vin
4
5
7
General tolerances: ±0.50mm[±0.020inch]
L=530mm[20.866inch] Devices per tube quantity: 40pcs
L=220mm[8.661inch] Devices per tube quantity: 16pcs
+Vo
0V
Short tube inner packaging dimensions: L*W*H=255*170*80mm
Short tube outer packaging dimensions
(with six inner packaging boxes):L*W*H=375*280*270mm
Long tube inner packaging dimensions: L*W*H=580*200*100mm
Long tube outer packaging dimensions
(with two inner packaging boxes):L*W*H=600*215*220mm
Long tube outer packaging dimensions
Note:
Unit:mm[inch]
Pin section tolerances:±0.10mm[±0.004inch]
General tolerances:±0.25mm[±0.010inch]
(with three inner packaging boxes):L*W*H=600*215*325mm
Note:
1. Operation under minimum load will not damage the converter; However, they may not meet all specification listed, and that will reduce the life
of product.
2. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
3. Only typical models listed, other models may be different, please contact our technical person for more details.
4. In this datasheet, all the test methods of indications are based on corporate standards.
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
F_M-1W & F_N-1W B/1-2012 Page 3 of 3