COMMON SPECIFICATION  
APPLICATION NOTE  
Item  
Test Conditions  
Min  
Typ  
15  
Max  
95  
Units  
%
Requirement on output load  
Storage humidity  
Operating temperature  
Storage temperature  
Temp. rise at full load  
Lead temperature  
Cooling  
To ensure this module can operate efficiently  
and reliably, During operation, the minimum  
output load is not less than 10% of the full  
load, and that this product should never be  
operated under no load! If the actual output  
power is very small, please connect a resistor  
with proper resistance at the output end in  
parallel to increase the load.  
-40  
-55  
85  
125  
25  
°C  
1.5mm from case for 10 seconds  
260  
Free air convection  
Isolation voltage  
Isolation resistance  
Short circuit protection*  
package material  
MTBF  
Tested for 1 minute and 1mA max  
Test at 500VDC  
3000  
1000  
VDC  
MΩ  
1
second  
Epoxy Resin(UL94-V0)  
3500 K hours  
Recommended circuit  
If you want to further decrease the  
input/output ripple, an LCfiltering network may  
be connected to the input and output ends of the  
DC/DC converter, see (Figure 1).  
Weight  
1.71  
g
*Supply voltage must be discontinued at the end of short circuit duration.  
L
TYPICAL CHARACTERISTICS  
L
+Vo  
Vin  
GND  
Cout  
Cin  
DC  
DC  
0V  
(Figure 1)  
It should also be noted that the inductance and  
the frequency of the LCfiltering network should  
be staggered with the DC/DC frequency to avoid  
mutual interference. However, the capacitance of  
the output filter capacitor must be proper. If the  
capacitance is too big, a startup problem might  
arise. Its not recommended to connect any  
external capacitor in the application field.  
Operating Temp.(oC)  
RECOMMENDED REFLOW SOLDERING PROFILE  
260o C  
250  
10 Sec Max  
220o C  
200  
150  
Output Voltage Regulation and Over-voltage  
Protection Circuit  
The simplest device for output voltage  
90 Sec Max  
(>220oC)  
regulation,  
over-voltage  
and  
over-current  
100  
protection is  
a
linear voltage regulator with  
overheat protection that is connected to the input  
50  
0
or output end in series (Figure2).  
Dual Ou tput  
Time (sec.)  
+Vout  
0V  
REG  
REG  
REG  
Vin  
REG  
OUTLINE DIMENSIONS & FOOTPRINT DETAILS  
DC DC  
GND  
-Vout  
First Angle Projection  
Single Output  
RECOMMENDED FOOTPRINT  
Top view,grid:2.54mm(0.1inch),  
diameter:1.00mm  
+Vout  
0V  
Vin  
REG  
DC  
DC  
Figure2)  
Overload Protection  
GND  
2.00  
(0.079)  
Under normal operating conditions, the output  
circuit of these products has no protection  
against overload. The simplest method is to  
connect a self-recovery fuse in series at the input  
end or add a circuit breaker to the circuit.  
(0.039)  
FOOTPRINT DETAILS  
No parallel connection or plug and play.  
Single  
Pin  
Dual  
2
1
Vin  
Vin  
GND  
0V  
GND  
0V  
NC  
-Vo  
+Vo  
NC  
8
+Vo  
NC  
Others  
Note:  
Unit:mm(inch)  
Pin section:0.50*0.30mm(0.020*0.012inch)  
Pin tolerances: 0.10mm( 0.004inch)  
General tolerances: 0.25mm( 0.010inch)  
MORNSUN reserves the copyright  
Specifications subject to change without notice.  
F_T-W2&E_T-W2  
A/0-2007  
Page 2 of 2