DC/DC Converter  
A_S-1WR2 & B_LS-1WR2 Series  
2. EMC typical recommended circuit (CLASS B)  
LDM  
Vin  
Vin  
+Vo  
Input voltage (VDC)  
C1  
3.3/5/9/12  
4.7μF /50V  
Refer to the Cout in Fig.3  
-- 1nF/2KV  
15/24  
DC/DC  
LOAD  
C1  
C2  
C2  
CY  
EMI  
-Vo  
(0V)  
GND  
GND  
LDM  
6.8μH  
CY  
Note: 1.15V/ 24V input series is subject to CY (CY : 1nF/2KV).  
2. It is not needed to add the component in the peripheral circuit  
when parameter with the symbol of "--".  
Fig. 4  
3. Output load requirements  
To ensure the module work efficiently and reliably, during the operation, the min. output load should be no less than 10% of the full load. If  
the actual output power is low, please connect a resister to the output terminal in parallel, with a recommenced resistance which is 10% of  
the rated power, and derating is required during operation.  
4. For more information please find the application notes on www.mornsun-power.com  
Dimensions and Recommended Layout  
Note:  
1. Packing Information please refer to 'Product Packing Information'. Packing bag number: 58200029;  
2. If the product is operated under the min. required load, the product performance cannot be guaranteed to comply with all  
performance indexes in this datasheet;  
3. The max. capacitive load should be tested within the input voltage range and under full load conditions;  
4. Unless otherwise specified, data in this data sheet should be tested under the conditions of Ta=25°C, humidity<75% when inputting  
nominal voltage and outputting rated load;  
5. All index testing methods in this datasheet are based on our Company’s corporate standards;  
6. The performance indexes of the product models listed in this manual are as above, but some indexes of non-standard model products  
will exceed the above-mentioned requirements, and please directly contact our technicians for specific information;  
7. We can provide product customization service;  
8. Specifications of this product are subject to changes without prior notice.  