欢迎访问ic37.com |
会员登录 免费注册
发布采购

MM1438 参数 Datasheet PDF下载

MM1438图片预览
型号: MM1438
PDF下载: 下载PDF文件 查看货源
内容描述: IC锂离子Betteries控制充电 [IC for Control of Lithium-ion Betteries Charging]
分类和应用:
文件页数/大小: 7 页 / 143 K
品牌: MITSUMI [ MITSUMI ELECTRONICS, CORP. ]
 浏览型号MM1438的Datasheet PDF文件第1页浏览型号MM1438的Datasheet PDF文件第2页浏览型号MM1438的Datasheet PDF文件第3页浏览型号MM1438的Datasheet PDF文件第4页浏览型号MM1438的Datasheet PDF文件第6页浏览型号MM1438的Datasheet PDF文件第7页  
IC for Control of Lithium-ion Betteries Charging MM1438  
MITSUMI  
(Except where noted otherwise, Ta=25°C, VCC=5V, SW3 : A, SW6 : A, SW7 : A)  
Measurement Procedures  
Measurement Procedures  
Item  
V3 = VCC, V4 = 0V. Next, measure A5 current value Icc1 when V3 is changed  
from VCC 0V.  
Consumption current 1  
Consumption current 2  
Output voltage  
V3 = Vd = VCC. Measure A6 current value ICC2 at this time.  
V3 = VCC, V4 = 0V. Measure T7 voltage VO at this time.  
V3 = Vcc, V4 = 0V. Set V7 voltage 1V lower than T7 (output voltage) potential  
and set SW7 to B. Measure T8 voltage VCL at this time.  
V3 = VCC, V4 = 0V, SW6: C. V7 = 4.5V, SW7: B. Measure A7 current value  
ICEL1 at this time.  
Current limit  
Inflow current between  
CEL-CS during operation  
V3 = V4 = VCC = 0V, SW6: C. V7 = 4.5V, SW7: B. Measure A7 current value  
ICEL2 at this time.  
Leak current between CEL-CS  
SW1 input current  
Measure A4 current value ISW1 when V4 = 0V.  
V3 = VCC. Charge: ON (VL1) when V4 potential is varied and T7 voltage is the  
prescribed output voltage; Charge OFF (VH1) when 0 ~ 0.05V.  
V3 = V4 = 0V. Set V7 voltage 1V lower than T7 (output voltage) potential, and  
SW7: B.  
SW1 input voltage  
L
ow voltage detection voltage  
Next gradually lower V7 voltage; V7 voltage is LV when A7 current value is  
within 10ꢀA.  
SW2 input current  
SW2 input voltage  
Measure A3 current value ISW2 when V3 = 0V.  
V4 = 0V, V7 = 1V, SW7: B. Low voltage detection circuit: ON (VL2) when V3  
voltage is varied and A7 current value is within 10ꢀA; low voltage detection  
circuit: OFF (VH2) otherwise.  
Low voltage detection  
output leak current  
V3 = VCC, V4 = 0V. Measure A2 current value ILV when V3 is changed from  
Vcc 0V.  
Low voltage detection  
V3 = V4 = 0V. SW3: B, SW7: B. Measure T2 voltage VLV when V7 voltage is 0V.  
output saturation voltage  
EXT pin inflow current  
EXT pin output voltage  
V3 = V4 = 0V. SW6: B, SW7: B, V6 = 4V, V7 = 3V. Measure A6 current value IEXT  
V3 = V4 = 0V. SW6: C, SW7: B. T6 voltage when V7 = 3V and V7 = 5V is VEXT  
.
.