PDSP16510A MA  
not go active until this priming has occurred. The DOS priming  
strobes must be enabled by the DEN input, unless the device  
hasbeen configuredinone ofthe multipledevicemodes(See  
section on Multiple Device Systems ).  
timingisgiveninTable2. ItshouldbenotedthattheDOSinput  
MUST be continually present before DAV goes active. If this  
is not the case the DAV output will not go active at the correct  
time, and the internal output circuitry will not be primed. Once  
DAV is active, however, it is possible for DOS to be irregular,  
and DEN can be used to inhibit the action of the output strobe  
as discussed previously. For the correct operation of the  
device the user must ensure that DOS becomes continuous  
and DEN remains low once DAV goes in-active.  
When continuously transforming data such that new  
outputs are internally available before the previous block has  
been completely dumped, then DAV would normally stay  
active and give no indication that one block dump had been  
finished andanotherblockstarted.Additionalinternalcircuitry  
is, however, providedtoensurethatDAVgoesinactiveforone  
DOS high time, thus supplying an inter block marker.  
The state of the DEN input at the end of a transform is  
used to control the transition of the active going edge of the  
DAV output with respect to the DOS strobes. The latter are  
then used to transfer data from the device to the next system  
component. If the DEN input is tied low in a single device  
system, the active going DAV transition will be internally  
synchronised to the rising edge of a DOS clock. If DEN is not  
tied low it must be guaranteed to be low at the end of the  
internal transform operation for this synchronization to occur.  
Since there is no external indication of this event, the user  
must take care to only allow DEN to go high whilst DAV is  
active, if this DAV synchronous mode is needed.  
ASYNCHRONOUS DAV MODE  
SYNCHRONIZED DAV OPERATION  
If DEN is not active in a single device when the transform  
is complete, then the device will wait for DEN to go active  
before any data is dumped. This mode is suitable for applica-  
tions in which output processing is under the control of a  
remote host, such as a general purpose digital signal proces-  
sor. The DAV output will then go active as soon as the output  
buffer is full, and will not be synchronised to the DOS edge. In  
such systems the DOS strobe may not necessarily be present  
at this time. Table 3 gives the relevant timing information.  
In this host controlled dump mode the PDSP16510 waits  
for the host to activate the DEN input after DAV has gone  
active. DEN then functions as an enable for the host produced  
data strobes on the DOS pin. DEN may either stay active for  
the complete transfer, or may be used to enable each DOS  
IntheDAVsynchronisedmodethefirst risingedgeofthe  
DOS clock, after DAV has gone active, must be used to  
transfer the first transformed sample from the output pins to  
the next system component. It should be noted that the output  
buffer will have been primed before the active DAV transition,  
since DOS must be a continuous clock, and there is then no  
delay before the first output becomes valid. The DAV output  
can be used as a clock enable for this next device, and  
transfers will continue in normal sequential order until the  
required data has been dumped. DAV will then go inactive in  
response to the last DOS edge which was used to transfer  
data to the next device.  
This mode of automatically dumping data when it is ready  
finds applications in real time data flow systems, and detailed  
16510A  
Symbol  
Min  
Max  
Units  
Characteristic  
TLZ  
THZ  
TDD  
TDH  
TVD  
TVI  
15  
15  
15  
ns  
ns  
ns  
ns  
ns  
ns  
Output Enable Time  
Output Disable Time  
Data Delay Time ( 30 pf load )  
Data Hold Time  
2
1
1
10  
10  
DAV active Delay Time ( 30 pf load )  
DAV in active Delay Time ( 30 pf load )  
Table 2. Output Timing with DEN tied low. ( Advanced Data )  