欢迎访问ic37.com |
会员登录 免费注册
发布采购

MT9074AP 参数 Datasheet PDF下载

MT9074AP图片预览
型号: MT9074AP
PDF下载: 下载PDF文件 查看货源
内容描述: T1 / E1 / J1单芯片收发器 [T1/E1/J1 Single Chip Transceiver]
分类和应用: 电信集成电路
文件页数/大小: 122 页 / 371 K
品牌: MITEL [ MITEL NETWORKS CORPORATION ]
 浏览型号MT9074AP的Datasheet PDF文件第20页浏览型号MT9074AP的Datasheet PDF文件第21页浏览型号MT9074AP的Datasheet PDF文件第22页浏览型号MT9074AP的Datasheet PDF文件第23页浏览型号MT9074AP的Datasheet PDF文件第25页浏览型号MT9074AP的Datasheet PDF文件第26页浏览型号MT9074AP的Datasheet PDF文件第27页浏览型号MT9074AP的Datasheet PDF文件第28页  
MT9074  
Advance Information  
N bytes of data. The HDLC does not distinguish  
between the control and information fields and a  
packet does not need to contain an information field  
to be valid.  
Frame Abort  
The transmitter will abort a current packet by  
substituting a zero followed by seven contiguous 1s  
in place of the normal packet. The receiver will abort  
upon reception of seven contiguous 1s occurring  
between the flags of a packet which contains at least  
26 bits.  
The FCS field, which precedes the closing flag,  
consists of two bytes. A cyclic redundancy check  
utilizing the CRC-CCITT standard generator  
16  
12  
5
polynomial “X +X +X +1” produces the 16-bit  
FCS. In the transmitter the FCS is calculated on all  
bits of the address and data field. The complement  
of the FCS is transmitted, most significant bit first, in  
the FCS field. The receiver calculates the FCS on  
the incoming packet address, data and FCS field and  
compares the result to “F0B8”. If no transmission  
errors are detected and the packet between the flags  
is at least 32 bits in length then the address and data  
are entered into the receive FIFO minus the FCS  
which is discarded.  
Note that should the last received byte before the  
frame abort end with contiguous 1s, these are  
included in the seven 1s required for a receiver  
abort. This means that the location of the abort  
sequence in the receiver may occur before the  
location of the abort sequence in the originally  
transmitted packet. If this happens then the last data  
written to the receive FIFO will not correspond  
exactly with the last byte sent before the frame abort.  
Interframe Time Fill and Link Channel States  
Data Transparency (Zero Insertion/Deletion)  
When the HDLC transmitter is not sending packets it  
will wait in one of two states  
Transparency ensures that the contents of a data  
packet do not imitate a flag, go-ahead, frame abort  
or idle channel. The contents of a transmitted frame,  
between the flags, is examined on a bit-by-bit basis  
and a 0 bit is inserted after all sequences of 5  
contiguous 1 bits (including the last five bits of the  
FCS). Upon receiving five contiguous 1s within a  
frame the receiver deletes the following 0 bit.  
Interframe Time Fill state: This is a  
continuous series of flags occurring between  
frames indicating that the channel is active  
but that no data is being sent.  
Idle state: An idle Channel occurs when at  
least 15 contiguous 1s are transmitted or  
received.  
In both states the transmitter will exit the wait state  
when data is loaded into the transmitter FIFO.  
Invalid Frames  
Go-Ahead  
A frame is invalid if one of the following four  
conditions exists (Inserted zeros are not part of a  
valid count):  
A go ahead is defined as the pattern "011111110"  
(contiguous 7Fs) and is the occurrence of a frame  
abort sequence followed by a zero, outside of the  
boundaries of a normal packet. Being able to  
If the FCS pattern generated from the  
received data does not match the “F0B8”  
pattern then the last data byte of the packet  
is written to the received FIFO with a ‘bad  
packet’ indication.  
distinguish  
a
proper (in packet) frame abort  
sequence from one occurring outside of a packet  
allows a higher level of signalling protocol which is  
not part of the HDLC specifications.  
A short frame exists if there are less than 25  
bits between the flags. Short frames are  
ignored by the receiver and nothing is written  
to the receive FIFO.  
Packets which are at least 25 bits in length  
but less than 32 bits between the flags are  
also invalid. In this case the data is written to  
the FIFO but the last byte is tagged with a  
“bad packet” indication.  
HDLC Functional Description  
The HDLC transceiver can be reset by either the  
power reset input signal or by the HRST Control bit  
in the test control register (software reset). When  
reset, the HDLC Control Registers are cleared,  
resulting in the transmitter and receiver being  
disabled. The Receiver and Transmitter can be  
enabled independent of one another through Control  
Register 1. The transceiver input and output are  
enabled when the enable control bits in Control  
Register 1 are set. Transmit to receive loopback as  
If a frame abort sequence is detected the  
packet is invalid. Some or all of the current  
packet will reside in the receive FIFO,  
assuming the packet length before the abort  
sequence was at least 26 bits long.  
24  
 复制成功!