MT8979 ISO-CMOS  
The multiframe synchronization algorithm is  
dependent upon the state of frame alignment framer.  
The multiframe framer will not initiate a search for  
multiframe synchronization until frame sync is  
synchronization is acquired, the CRC framer must  
find two framing signals in bit 1 of the non-frame  
alignment signal. Upon detection of the second CRC  
framing signal the MT8979 will immediately go into  
CRC synchronization. When maintenance feature is  
enabled (maint bit = 1) the CRC framer will force a  
complete reframe of the device if CRC frame  
synchronization is not found within 8 ms or more  
than 914 CRC errors occur per second.  
achieved.  
Multiframe synchronization will be  
declared on the first occurrence of four consecutive  
zeros in the higher order quartet of channel 16.  
Once multiframe synchronization is achieved, the  
framer will only go out of synchronization after  
detection of two errors in the multiframe signal or  
loss of frame alignment synchronization.  
The CRC synchronization algorithm is also  
dependent on the state of the frame alignment  
framer, but is independent of the multiframe  
synchronization. The CRC framer will not initate a  
search for CRC framing signal until frame alignment  
synchronization is achieved. Once frame alignment  
out of  
synchronization  
No  
search for frame  
alignment  
signal  
Yes  
No  
verify bit 2 of non-  
frame alignment  
signal  
# of consecutive incorrect  
frame alignment signals = 3  
Yes  
No  
verify second  
occurrence of frame  
alignment signal  
time out > 8ms  
Yes  
frame synchroni-  
zation acquired  
No  
find two CRC  
search for  
frame alignment  
signals  
multiframe align-  
ment signal  
number of CRC  
errors > 914/s  
Yes  
Yes  
multiframe synchro-  
nization acquired  
CRC synchronization  
acquired  
Yes  
check for two errored  
multiframe alignment  
signals  
- - - - - Only if the  
maintenance  
option is  
No  
selected  
Figure 13 - Synchronization State Diagram  