MT8952B ISO-CMOS
The timing signals like CKi (C2i or C4i) and F0i
are provided externally at the primary end and at the
secondary end, they are derived from the received
data.
Secondary End of the Link:
At the secondary end of the communication link, a
similar procedure is adopted to transmit/receive the
data and control information.
Although
this
application
describes
the
a
communication between two stations over
The MT8952B operates in the Internal Timing Mode
as at the primary end, but the DNIC (MT8972) is
selected to operate in single port, slave mode with
the digital network capability enabled.
dedicated link, it can be modified to serve a switched
communication path by additional control functions
and a call set-up procedure many of which can be
achieved in software.
The other functions and procedures are similar to
those at the primary end.
3-76