MH88630
Absolute Maximum Ratings*
-
Voltages are with respect to AGND.
Parameters
1
DC Supply Voltages
Preliminary Information
Sym
V
DD
-GNDA
V
EE
-GNDA
V
CC+
-GNDA
V
CC-
-GNDA
Min.
-0.3
-6.0
Max
+6.0
+0.3
+18.0
Units
V
V
V
V
-18.0
-55
+125
2
Storage Temperature
T
STG
°C
*
Exceeding these values may cause damage. Functional operation under these conditions is not implied.
Recommended Operating Conditions
Parameters
1
Operating Supply Voltage
Sym
V
DD
V
EE
V
CC+
V
CC-
2
Operating Current
V
Bat
I
DD
I
EE
I
CC+
I
CC-
3
4
Power Consumption
Operating Temperature
P
C
T
OP
0
Min.
4.75
-5.25
11.4
-11.4
Typ
‡
5.0
-5.0
12.0
12.0
-48
7.0
-7.0
8.0
-8.0
265
70
Max
5.25
-4.75
12.6
-12.6
Units
V
V
V
V
V
mA
mA
mA
mA
mW
°C
RINGND High
Comments
‡ Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing.
Control Inputs State Table
Parameter
1
2
3
4
RC1
RC2
RINGND
NETBAL
AT&T compromise network
(350Ω + 1kΩ // 0.21µF)
6000Ω network
Active
Logic High
Logic High
Logic Low
Idle
Logic Low
Logic Low
Logic High
AGND
Open (no connection)
2-220