Preliminary Information
Absolute Maximum Ratings*
Parameter
1
DC Supply Voltage
Symbol
V
DD
V
EE
V
Bat
T
STG
P
D
Min
-0.3
+0.3
0.3
-40
Max
+15
-15
-60
100
2
MH88612K
Units
V
V
V
°C
W
2
3
Storage Temperature
Package Power Dissipation
* Exceeding these values may cause permanent damage. Functional operation under these conditions is not implied.
Recommended Operating Conditions
Characteristics
1
Operating Supply Voltage
Sym
V
DD
V
EE
V
Ref
V
Bat
V
RLY
2
Operating Temperatures
T
O
0
-27
Min
4.75
-4.75
Typ
†
5.0
-5.0
0
-48
5
70
-60
Max
5.25
-5.25
Units
V
V
V
V
V
°C
Adjustable
Comments
† Typical figures are at 25°C and are for design aid only.
2-125