MH88600
Absolute Maximum Ratings*
- Voltages are with respect to AGND.
Parameters
1
DC Supply Voltages
Sym
V
DD
V
EE
(GNDA = GND
Bat
)
V
Bat
V
RR
2
3
Storage Temperature
Power Dissipation
T
S
P
D
Preliminary Information
Min.
-0.3
+0.3
+0.3
-0.3
-55
Max
15
-15
-80
40
125
4
Units
V
V
V
V
°C
W
.
* Exceeding these values may cause permanent damage. Functional operation under these conditions is not implied.
Recommended Operating Conditions
Characteristics
1
Operating Supply Voltage
Sym
V
DD
V
EE
V
Bat
V
RR
2
Operating Temperature
T
OP
0
Min.
4.75
-5.25
-72
Typ
*
5.0
-5.0
-48
5
Max
5.25
-4.75
-24
24
70
Units
V
V
V
V
°C
Comments
* Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing.