MIHW3000 Series
Output Specifications
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Conditions
Min.
---
Typ.
{0.5
{0.5
{0.3
{0.5
75
Max.
{1.0
{2.0
{0.5
{1.0
100
Unit
%
Dual Output, Balanced Loads
Vin=Min. to Max.
---
%
---
%
Load Regulation
Io=100% to 25%
---
%
5V Output Models
---
mV P-P
mV P-P
mV P-P
mV rms
%
Ripple & Noise (20MHz)
Other Output Models
Over Line, Load & Temp.
---
100
150
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Over Load
---
---
---
---
300
180
---
25
120
---
500
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
---
uS
25% Load Step Change
---
{3
{6
%
---
{0.02
{0.05
%/]
Continuous
General Specifications
Parameter
Isolation Voltage Rated
Isolation Voltage Test
Leakage Current
Conditions
60 Seconds
Min.
5600
6000
---
1000
---
---
700
Typ.
---
---
---
---
7
Max.
---
---
2
Unit
VDC
VDC
uA
Flash Tested for 1 Second
240VAC, 60Hz
500VDC
Isolation Resistance
Isolation Capacitance
Switching Frequency
MTBF
---
13
M[
100KHz,1V
pF
150
---
---
KHz
K Hours
MIL-HDBK-217F @ 25], Ground Benign
---
Notes :
1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted.
2. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.
3. Ripple & Noise measurement bandwidth is 0-20 MHz.
4. These power converters require a minimum output loading to maintain specified regulation.
5. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed.
6. All DC/DC converters should be externally fused at the front end for protection.
7. Other input and output voltage may be available, please contact factory.
8. Specifications subject to change without notice.
REV:5 2009/02/02