MIHW3000 Series  
Output Specifications  
Parameter  
Output Voltage Accuracy  
Output Voltage Balance  
Line Regulation  
Conditions  
Min.  
---  
Typ.  
{0.5  
{0.5  
{0.3  
{0.5  
75  
Max.  
{1.0  
{2.0  
{0.5  
{1.0  
100  
Unit  
%
Dual Output, Balanced Loads  
Vin=Min. to Max.  
---  
%
---  
%
Load Regulation  
Io=100% to 25%  
---  
%
5V Output Models  
---  
mV P-P  
mV P-P  
mV P-P  
mV rms  
%
Ripple & Noise (20MHz)  
Other Output Models  
Over Line, Load & Temp.  
---  
100  
150  
Ripple & Noise (20MHz)  
Ripple & Noise (20MHz)  
Over Load  
---  
---  
---  
---  
300  
180  
---  
25  
120  
---  
500  
Transient Recovery Time  
Transient Response Deviation  
Temperature Coefficient  
Output Short Circuit  
---  
uS  
25% Load Step Change  
---  
{3  
{6  
%
---  
{0.02  
{0.05  
%/]  
Continuous  
General Specifications  
Parameter  
Isolation Voltage Rated  
Isolation Voltage Test  
Leakage Current  
Conditions  
60 Seconds  
Min.  
5600  
6000  
---  
1000  
---  
---  
700  
Typ.  
---  
---  
---  
---  
7
Max.  
---  
---  
2
Unit  
VDC  
VDC  
uA  
Flash Tested for 1 Second  
240VAC, 60Hz  
500VDC  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
MTBF  
---  
13  
M[  
100KHz,1V  
pF  
150  
---  
---  
KHz  
K Hours  
MIL-HDBK-217F @ 25], Ground Benign  
---  
Notes :  
1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted.  
2. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.  
3. Ripple & Noise measurement bandwidth is 0-20 MHz.  
4. These power converters require a minimum output loading to maintain specified regulation.  
5. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed.  
6. All DC/DC converters should be externally fused at the front end for protection.  
7. Other input and output voltage may be available, please contact factory.  
8. Specifications subject to change without notice.  
REV:5 2009/02/02  
MINMAX  
3