AHF-10 Series
Model Selection Guide
Model Number
Output Voltage
Output Current
Capacitive Load
Input Current
115VAC, 60Hz
Efficiency
Max.
mA
Min.
mA
Max.
uF
@Max. Load
mA (Typ.)
137
@No Load
mA (Typ.)
@Max. Load
% (Typ.)
VDC
3.3
5
AHF-10S03
AHF-10S05
AHF-10S12
AHF-10S15
AHF-10S24
AHF-10D12
AHF-10D15
2000
2000
833
200
200
83
3900
3300
15
15
15
15
15
15
15
70
73
76
76
76
77
77
199
12
2200
191
15
666
66
2200
191
24
416
42
1000
190
{12
{15
{380
{300
{38
{30
# 1000
# 1000
172
169
# For each output.
Note :
Environmental Specifications
Parameter
Operating Temperature
Storage Temperature
Humidity
Conditions
Min.
Max.
Unit
]
1. Specifications typical at Ta=+25], resistive
load, 115VAC, 60Hz input voltage, rated
output current unless otherwise noted.
Ambient
-25
-40
---
71
85
95
]
%
2. Ripple & Noise measurement bandwidth is
0-20 MHz.
Cooling
Free-Air Convection
EN55022 Class B
3. These power modules require a minimum
output loading to maintain specified
regulation.
Conducted EMI
specification
requirement
Performance
Criteria
Standard
4. Operation under no-load conditions will not
damage these devices; however they may not
meet all listed specifications.
Air {8KV
Cont. {4KV
EN61000-4-2
B
5. Other input and output voltage may be
available, please contact factory.
80~1000MHz 10V/m
80% AM1KHz
modulation
EN61000-4-3
EN61000-4-4
EN61000-4-5
A
6. Specifications subject to change without
notice.
AC port {2KV
DC, SL, TL {2KV
not less than 1 min.
B
B
Conducted EMC
1.2/50uS(8/20uS)
AC dif. {1KV
DC {0.5KV
0.15~80MHz 10Vrms
(functional earth ports
included)
EN61000-4-6
EN61000-4-11
B
80% AM 1kHz
modulation
30% 10ms
60% 100ms
95% 5000ms
B
C
C
Input Specifications
Parameter
Input Voltage Range
Conditions
Min.
85
Typ.
---
---
---
---
Max.
265
440
10
Unit
VAC
Hz
A
All Models
Input Frequency Range
47
115VAC
230VAC
---
---
Inrush Current (Cold Start at 25])
20
A
REV:9 2008/10