AGF-10 Series
Model Selection Guide
Model
Number
Output Voltage
Output Current
Input Current
115VAC, 60Hz
Capacitive Load
Efficiency
Max.
uF
Max.
mA
2500
2000
833
Min.
mA
250
200
83
@Max. Load
mA (Typ.)
171
@No Load
mA (Typ.)
@Max. Load
% (Typ.)
70
VDC
3.3
5
AGF-10S03
AGF-10S05
AGF-10S12
AGF-10S15
AGF-10S24
15
15
15
15
15
2200
2200
1000
1000
680
201
72
12
191
76
15
667
67
193
75
24
417
42
201
72
Input Fuse Selection Guide
All Models
External Fuse (Recommended)
1.5A Slow - Blow Type
Input Specifications
Parameter
Input Voltage Range
Model
Min.
90
Typ.
---
---
---
---
Max.
Unit
VAC
Hz
A
264
440
15
All Models
Input Frequency Range
47
115VAC
230VAC
---
---
Inrush Current (Cold Start at 25])
30
A
Output Specifications
Parameter
Output Voltage Accuracy
Line Regulation
Conditions
Min.
---
---
---
---
---
---
---
---
Typ.
{1.0
{0.5
{0.5
1.5
Max.
{2.0
{1.0
{1.0
1.8
Unit
%
%
Vin=Min. to Max.
Io=Min. to Max.
Load Regulation
%
3.3 & 5.0VDC Output Models
Other Output Models
%Vpp of Vo
%Vpp of Vo
% of Vo
%/]
%
Ripple & Noise (20MHz)
0.8
1.0
Over Voltage Protection
Temperature Coefficient
Overshoot
Zener diode clamp
120
---
{0.02
5
{0.01
---
---
Current limitation
85VAC, Hiccup technique, auto-recovery
105
---
%
Short circuit protection
Hiccup mode, indefinite (automatic recovery)
General Specifications
Parameter
Isolation Voltage Rated
Isolation Voltage Test
Isolation Resistance
Switching Frequency
Hold-up Time
Conditions
Input to Output, 60 Seconds
Input to output, Flash Tested for 1 Second
500VDC
Min.
3000
4700
100
Typ.
---
---
---
125
Max.
---
---
---
---
---
---
Unit
VAC
VDC
M[
---
---
330
KHz
115VAC, 60Hz
15
ms
MTBF
MIL-HDBK-217F @ 25], Ground Benign
---
K Hours
REV:5 2009/02/16
MINMAX