欢迎访问ic37.com |
会员登录 免费注册
发布采购

CMM1100-BD_10 参数 Datasheet PDF下载

CMM1100-BD_10图片预览
型号: CMM1100-BD_10
PDF下载: 下载PDF文件 查看货源
内容描述: 2.0-18.0 GHz的砷化镓MMIC [2.0-18.0 GHz GaAs MMIC]
分类和应用:
文件页数/大小: 9 页 / 1690 K
品牌: MIMIX [ MIMIX BROADBAND ]
 浏览型号CMM1100-BD_10的Datasheet PDF文件第1页浏览型号CMM1100-BD_10的Datasheet PDF文件第2页浏览型号CMM1100-BD_10的Datasheet PDF文件第3页浏览型号CMM1100-BD_10的Datasheet PDF文件第4页浏览型号CMM1100-BD_10的Datasheet PDF文件第5页浏览型号CMM1100-BD_10的Datasheet PDF文件第6页浏览型号CMM1100-BD_10的Datasheet PDF文件第7页浏览型号CMM1100-BD_10的Datasheet PDF文件第8页  
2.0-18.0 GHz GaAs MMIC
Low Noise Amplifier
February 2010 - Rev-05-Feb-10
CMM1100-BD
Handling and Assembly Information
CAUTION!
- Mimix Broadband MMIC Products contain gallium arsenide (GaAs) which can be hazardous to the
human body and the environment. For safety, observe the following procedures:
• Do not ingest.
• Do not alter the form of this product into a gas, powder, or liquid through burning, crushing, or chemical
processing as these by-products are dangerous to the human body if inhaled, ingested, or swallowed.
• Observe government laws and company regulations when discarding this product. This product must be
discarded in accordance with methods specified by applicable hazardous waste procedures.
Life Support Policy
- Mimix Broadband's products are not authorized for use as critical components in life support
devices or systems without the express written approval of the President and General Counsel of Mimix Broadband. As
used herein: (1) Life support devices or systems are devices or systems which, (a) are intended for surgical implant into
the body, or (b) support or sustain life, and whose failure to perform when properly used in accordance with
instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user.
(2) A critical component is any component of a life support device or system whose failure to perform can be
reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
ESD
- Gallium Arsenide (GaAs) devices are susceptible to electrostatic and mechanical damage. Die are supplied in
antistatic containers, which should be opened in cleanroom conditions at an appropriately grounded antistatic work-
station. Devices need careful handling using correctly designed collets, vacuum pickups or, with care, sharp tweezers.
Die Attachment
- GaAs Products from Mimix Broadband are 0.076 mm (0.003") thick and have vias through to the
backside to enable grounding to the circuit. Microstrip substrates should be brought as close to the die as possible. The
mounting surface should be clean and flat. If using conductive epoxy, recommended epoxies are Tanaka TS3332LD, Die
Mat DM6030HK or DM6030HK-Pt cured in a nitrogen atmosphere per manufacturer's cure schedule. Apply epoxy
sparingly to avoid getting any on to the top surface of the die. An epoxy fillet should be visible around the total die
periphery. For additional information please see the Mimix "Epoxy Specifications for Bare Die" application note. If
eutectic mounting is preferred, then a fluxless gold-tin (AuSn) preform, approximately 0.001
2
thick, placed between the
die and the attachment surface should be used. A die bonder that utilizes a heated collet and provides scrubbing action
to ensure total wetting to prevent void formation in a nitrogen atmosphere is recommended. The gold-tin eutectic
(80% Au 20% Sn) has a melting point of approximately 280º C (Note: Gold Germanium should be avoided). The work
station temperature should be 310ºC +/- 10ºC. Exposure to these extreme temperatures should be kept to minimum.
The collet should be heated, and the die pre-heated to avoid excessive thermal shock. Avoidance of air bridges and
force impact are critical during placement.
Wire Bonding
- Windows in the surface passivation above the bond pads are provided to allow wire bonding to the
die's gold bond pads. The recommended wire bonding procedure uses 0.076 mm x 0.013 mm (0.003" x 0.0005") 99.99%
pure gold ribbon with 0.5-2% elongation to minimize RF port bond inductance. Gold 0.025 mm (0.001") diameter
wedge or ball bonds are acceptable for DC Bias connections. Aluminum wire should be avoided. Thermo-compression
bonding is recommended though thermosonic bonding may be used providing the ultrasonic content of the bond is
minimized. Bond force, time and ultrasonics are all critical parameters. Bonds should be made from the bond pads on
the die to the package or substrate. All bonds should be as short as possible.
Part Number for Ordering
CMM1100-BD-000W
PB-CMM1100-BD-0000
Description
RoHS compliant die packed in waffle trays
CMM1100-BD evaluation module
Appropriate precautions in handling, packaging
and testing devices must be observed.
Caution: ESD Sensitive
Proper ESD procedures should be followed when handling this device.
Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099
Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com
Page 9 of 9
Characteristic Data and Specifications are subject to change without notice.
©2010
Mimix Broadband, Inc.
Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept