3.3-3.6 GHz InGaP HBT
8W Linear Power Amplifier
February 2008 - Rev 29-Feb-08
CHV2721-QJ
App Note [1] Biasing
- The CHV2720-QJ requires power supply sequencing. Vcc should be applied first and then Vcontrol. Quiescent
current (Icq) can be varied by adjusting Vcontrol in order to obtain the optimum performance desired. RF power is applied after both Vcc
and Vcontrol are present. When turning off the device Vcontrol is switched off first and then Vcc. Vcontrol can be used to turn off the current.
Pin Assignment:
Functional Block Diagram:
Vcontrol
Active
Bias
Pin #
Description
Vcontrol
RF IN
RF OUT 4
RF OUT 3
RF OUT 2
RF OUT 1
N/C
RFout
RFout
1
4
14
15
16
17
2, 3, 5, 6, 7, 8, 9, 10, 11, 12
13, 18, 19, 20, 21, 22, 23, 24
RFin
Input Match
Output
Match
RFout
RFout