DC-2.5 GHz InGaP HBT
Matched Gain Block Amplifier
May 2006 - Rev 23-May-06
CGB7289-SC
Unless otherwise specified, the following specifications are guaranteed at room temperature in a Mimix test fixture.
Parameter
Temperature (ºC)
Min.
900 MHz
Typ.
Max.
Min.
1960 MHz
Typ.
Max.
Min.
2140 MH
Typ.
Max.
Units
Electrical Characteristics (8V, Active Bias)
Small Signal Gain
Output P1dB
Output IP3
Noise Figure
Operating Current
Input Return Loss
Output Return Loss
Pout @ -45 dBc, ACP
IS-95, 9 Forward Channels
+25
-40 to +85
+25
-40 to +85
+25
-40 to +85
+25
-40 to +85
+25
-40 to +85
+25
-40 to +85
+25
-40 to +85
+25
-40 to +85
20.0
19.7
22.3
22.0
38.5
37.5
21.0
21.0
23.3
23.3
40.0
40.0
3.8
3.8
120
120
15
15
7.5
7.5
16.5
16.5
22.0
22.3
13.7
13.4
23.0
22.7
40.0
39.0
14.7
14.7
24.0
24.0
41.5
41.5
4.7
4.7
120
120
12
12
15.0
15.0
17.5
17.5
15.7
16.0
12.5
12.2
23.0
22.7
40.5
39.5
110
105
11
10
5.5
5.0
4.8
5.3
130
135
110
105
9.0
8.5
11.0
10.0
5.5
6.0
130
135
110
105
10
9
9.0
8.5
13.5
13.5
24.0
24.0
42.0
42.0
5.3
5.3
120
120
13
13
12.0
12.0
14.5
14.8
6.4
6.5
130
135
dB
dB
dBm
dBm
dBm
dBm
dB
dB
mA
mA
dB
dB
dB
dB
dBm
dBm
Notes: 1. Test Conditions in Mimix eval board, Vs = 8 V, Id = 120 mA Typ., Rbias = 27
2. Values reflect performance in recommended application circuit.
, Zs = Zl = 50
, OIP3 tone spacing = 1 MHz, Pout per tone = 11 dBm.
Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099
Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com
Page 2 of 19
Characteristic Data and Specifications are subject to change without notice.
©2006
Mimix Broadband, Inc.
Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept
their obligation to be compliant with U.S. Export Laws.