0.1-10.0 GHz Low Noise, Medium Power
pHEMT in a Surface Mount Plastic Package
September 2007 - Rev 28-Sep-07
CFS0303-SB
Typical Performance
Nfmin vs. Frequency and Current, Vd=3V
1.4
2
25
Associated Gain vs. Frequency and Current, Vd=3V
2
5mA
1.2
20
1
NFmin (dB)
10 mA
15mA
20mA
Gain (dB)
0.8
15
40mA
60mA
0.6
5mA
10 mA
0.4
10
15mA
20mA
5
0.2
40mA
60mA
0
10
0
0
2
4
Frequency (GHz)
6
8
0
1
2
3
4
5
6
Frequency (GHz)
7
8
9
10
Nfmin and Associated Gain vs. Frequency and Temperature, Vd=3V, Ids=20mA
1
22
20
18
16
Ga??
25deg
85deg
40deg
NFmin
1.05
0.9
0.75
0.6
0.45
0.3
1.5
1.35
1.2
OIP3 and P1dB vs. Frequency and Temperature, Vds=3V, Ids=20mA
30
1,2
25
OIP3
14
12
10
8
6
4
2
0
2
4
6
8
10
Frequency (GHz)
OIP3, P1dB (dBm)
Ga (dB)
NFmin (dB)
20
15
P
1dB
25deg
10
-40deg
85deg
5
1
2
3
4
5
6
Frequency (GHz)
0.15
0
Notes:
1. P1dB and OIP3 measurements are performed with passive biasing. Idsq is set with zero RF drive applied. As P1dB is approached, the drain current may
increase or decrease depending on frequency and DC bias point. At lower values of Idsq the device is running in a Class AB mode and current tends to rise
as P1dB is approached. As an example, at a Vds = 3.0V and Idsq = 10 mA, Id increases to 30 mA as P1dB of 16.5 is approached. This rise in current is no
longer present as Idsq approaches 60 mA.
2. Measurements made on a fixed tuned test system set for optimum noise match. Circuit losses have been de-embedded for the actual measurements.
Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099
Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com
Page 5 of 17
Characteristic Data and Specifications are subject to change without notice.
©2007
Mimix Broadband, Inc.
Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept