TABLE I. Electrical performance characteristics - Continued.
Test
Symbol
Conditions
-55 C TA +125 C
Group A
subgroups
Limits
Min
Unit
unless otherwise specified
DC rapid tests 4/
Max
Case 2
High level output voltage VOH
Outputs
VIH
VIL
terminated
through
-0.807
-0.680
-0.870
-0.807
-0.680
-0.870
-1.135
-0.988
-1.188
-1.135
-0.988
-1.188
-1.950
-1.950
-1.950
-1.950
-1.950
-1.950
-1.488
-1.474
-1.519
-1.488
-1.474
-1.519
1
2
3
1
2
3
1
2
3
1
2
3
1
-1.035
-0.888
-1.088
-1.950
-1.950
-1.950
-1.035
-0.888
-1.088
-1.950
-1.950
-1.950
-74
-0.807
-0.680
-0.870
-1.588
-1.574
-1.619
-0.807
-0.680
-0.870
-1.588
-1.574
-1.619
V
V
V
100 to -2 V
VCC = 0.0 V
VEE = -5.2 V
2/
Low level output voltage
VOL
High level threshold
ouput voltage
VOHA
Low level threshold
output voltage
VOLA
V
Power supply
IEE
VEE = -5.46 V
mA
VCC = 0.0 V
drain current 3/
2, 3
1
-82
VIH = -0.807 V at 25 C
-0.680 V at +125 C
-0.870 V at -55 C
High level input current
IIH
All
305
495
A
A
2, 3
1, 3
Low level input current
IIL
VEE = -4.94 V
VCC = 0.0 V
3/
0.5
0.3
VIL = -1.950 V
See 4.3.1c
2
Functional tests
7, 8
See footnotes at end of table.
SIZE
STANDARD
5962-87729
A
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
REVISION LEVEL
D
SHEET
8
DSCC FORM 2234
APR 97