 浏览型号5962-9084202MPA的Datasheet PDF文件第4页浏览型号5962-9084202MPA的Datasheet PDF文件第5页浏览型号5962-9084202MPA的Datasheet PDF文件第6页浏览型号5962-9084202MPA的Datasheet PDF文件第7页浏览型号5962-9084202MPA的Datasheet PDF文件第8页浏览型号5962-9084202MPA的Datasheet PDF文件第9页浏览型号5962-9084202MPA的Datasheet PDF文件第11页浏览型号5962-9084202MPA的Datasheet PDF文件第12页  
TABLE II. Electrical test requirements.  
Subgroups  
Test requirements  
Subgroups  
(in accordance with  
MIL-STD-883,  
(in accordance with  
MIL-PRF-38535, table III)  
method 5005, table I)  
Device  
class M  
Device  
class Q  
Device  
class V  
Interim electrical  
----  
----  
----  
parameters (see 4.2)  
Final electrical  
parameters (see 4.2)  
1,2,3,4, 1/  
5,6,7  
1,2,3,4,  
5,6,7  
1/  
1,2,3,4,  
5,6,7  
1/  
Group A test  
1,2,3,4,5,6,7  
1,2,3,4,5,6,7  
1,2,3,4,5,6,7  
requirements (see 4.4)  
Group C end-point electrical  
parameters (see 4.4)  
1
1
1,2,3,4,5,6,7  
Group D end-point electrical  
parameters (see 4.4)  
1
1
1
Group E end-point electrical  
parameters (see 4.4)  
---  
---  
---  
1/ PDA applies to subgroup 1.  
4.4.4 Group E inspection. Group E inspection is required only for parts intended to be marked as radiation hardness assured  
(see 3.5 herein).  
a. End-point electrical parameters shall be as specified in table II herein.  
b. For device classes Q and V, the devices or test vehicle shall be subjected to radiation hardness assured tests as  
specified in MIL-PRF-38535 for the RHA level being tested. For device class M, the devices shall be subjected to  
radiation hardness assured tests as specified in MIL-PRF-38535, appendix A for the RHA level being tested. All device  
classes must meet the post irradiation end-point electrical parameter limits as defined in table I at  
TA = +25°C ±5°C, after exposure, to the subgroups specified in table II herein.  
5. PACKAGING  
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535 for device classes  
Q and V or MIL-PRF-38535, appendix A for device class M.  
6. NOTES  
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications  
(original equipment), design applications, and logistics purposes.  
6.1.1 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor  
prepared specification or drawing.  
6.1.2 Substitutability. Device class Q devices will replace device class M devices.  
6.2 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated with the users of record for  
the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal.  
SIZE  
STANDARD  
MICROCIRCUIT DRAWING  
5962-90842  
A
DEFENSE SUPPLY CENTER COLUMBUS  
COLUMBUS, OHIO 43218-3990  
REVISION LEVEL  
C
SHEET  
10  
DSCC FORM 2234  
APR 97