ADVANCE INFORMATION
VPC 323xD, VPC 324xD
4.6.4.5. Characteristics, FPDAT Input/Output
Symbol
Parameter
Pin Name
Min.
–
Typ.
Max.
0.5
–
Unit
V
Test Conditions
V
Output Low Voltage
Output Hold Time
Output Delay Time
Input Low Voltage
Input High Voltage
Input Setup Time
Input Hold Time
Load capacitance
FPDAT
–
–
–
–
–
–
–
–
I
= 4.0 mA
OL
OL
t
t
6
ns
ns
V
OH
ODL
–
35
0.8
–
C
L
= 40 pF
V
V
–
IL
1.5
7
V
IH
t
t
–
ns
ns
pF
IS
IH
5
–
C
40
L
4.6.4.6. Characteristics, I2C Bus Interface
Symbol
Parameter
Pin Name
Min.
–
Typ.
Max.
1.0
–
Unit
V
Test Conditions
V
V
V
Input Low Voltage
Input High Voltage
Output Low Voltage
SDA, SCL
–
–
–
IL
2.0
–
V
IH
OL
0.4
0.6
V
V
I = 3 mA
l
I = 6 mA
l
V
Input Capacitance
–
–
–
–
–
–
–
–
–
5
pF
ns
IH
t
t
f
t
t
t
t
Signal Fall Time
–
300
300
400
–
C
C
= 400 pF
= 400 pF
F
L
L
Signal Rise Time
–
ns
R
Clock Frequency
SCL
SDA
0
kHz
µs
µs
ns
SCL
Low Period of SCL
High Period of SCL
Data Set Up Time to SCL high
DATA Hold Time to SCL low
1.3
0.6
100
0
LOW
–
HIGH
SU Data
HD Data
–
0.9
µs
Micronas
63