欢迎访问ic37.com |
会员登录 免费注册
发布采购

VCT3801A 参数 Datasheet PDF下载

VCT3801A图片预览
型号: VCT3801A
PDF下载: 下载PDF文件 查看货源
内容描述: 视频/控制/图文电视IC系列 [Video/Controller/Teletext IC Family]
分类和应用: 电视
文件页数/大小: 172 页 / 2219 K
品牌: MICRONAS [ MICRONAS ]
 浏览型号VCT3801A的Datasheet PDF文件第22页浏览型号VCT3801A的Datasheet PDF文件第23页浏览型号VCT3801A的Datasheet PDF文件第24页浏览型号VCT3801A的Datasheet PDF文件第25页浏览型号VCT3801A的Datasheet PDF文件第27页浏览型号VCT3801A的Datasheet PDF文件第28页浏览型号VCT3801A的Datasheet PDF文件第29页浏览型号VCT3801A的Datasheet PDF文件第30页  
VCT 38xxA  
ADVANCE INFORMATION  
In each field two sets of measurements can be taken:  
tube measurement  
picture meas. start  
a) The picture tube measurement returns results for  
– cutoff R  
active video  
field 1/ 2  
– cutoff G  
– cutoff B  
picture meas. end  
– white-drive R or G or B (sequentially)  
b) The picture measurement returns data on  
– active picture maximum current  
– active picture minimum current  
small window for tube  
measurement (cutoff, white drive)  
large window for active picture  
The tube measurement is automatically started when  
the cutoff blue result register is read. Cutoff control for  
RGB requires one field only, whereas a complete  
white-drive control requires three fields. If the mea-  
surement mode is set to ‘offset check’, a measurement  
cycle is run with the cutoff/white-drive signals set to  
zero. This allows to compensate the MADC offset as  
well as input the leakage currents. During cutoff and  
white-drive measurements, the average beam current  
limiter function (see Section 2.11.3. on page 27) is  
switched off and a programmable value is used for the  
brightness setting. The start line of the tube measure-  
ment can be programmed via I2C bus, the first line  
used for the measurement, i.e. measurement of cutoff  
red, is 2 lines after the programmed start line.  
picture meas. start  
Fig. 2–21: Windows for tube and picture measure-  
ments  
2.11.2.SCART Output Signal  
The RGB output of the VCT 38xxA can also be used to  
drive a SCART output. In the case of the SCART sig-  
nal, the parameter CLMPR (clamping reference) has to  
be set to 1. Then, during blanking, the RGB outputs  
are automatically set to 50 % of the maximum bright-  
ness. The DC offset values can be adjusted with the  
cutoff parameters CR, CG, and CB. The amplitudes  
can be adjusted with the drive parameters WDR,  
WDG, and WDB.  
The picture measurement must be enabled by the con-  
trol microprocessor after reading the min./max. result  
registers. If a ‘1’ is written into bit 2 in subaddress 25,  
the measurement runs for one field. For the next mea-  
surement a ‘1’ has to be written again. The measure-  
ment is always started at the beginning of active video.  
The vertical timing for the picture measurement is pro-  
grammable, and may even be a single line. Also the  
signal bandwidth is switchable for the picture measure-  
ment.  
Two horizontal windows are available for the picture  
measurement. The large window is active for the entire  
active line. Tube measurement is always carried out  
with the small window. Measurement windows for pic-  
ture and tube measurement are shown in Fig. 2–21.  
26  
Micronas  
 复制成功!