PRELIMINARY DATA SHEET
MSP 44x8G
3.5.4. FM-Stereo Radio
<80 00 80 00>
<80 00 00 00>
// Softreset
<80 10 00 30 20 03> // MODUS-Register: Automatic = on
<80 12 00 08 03 20> // Source Sel. = (St or A) & Ch. Matr. = St
<80 12 00 0E 24 03> // FM/AM-Prescale = 24
,
hex
FM-Matrix = Sound A Mono
<80 10 00 20 00 40> // Standard Select: FM-STEREO-RADIO
<80 12 00 00 73 00> // Main Volume 0 dB
3.5.5. Automatic Standard Detection
A detailed software flow diagram is shown in Fig. 3–2
on page 36.
<80 00 80 00>
<80 00 00 00>
// Softreset
<80 10 00 30 20 03> // MODUS-Register: Automatic = on
<80 12 00 08 03 20> // Source Sel. = (St or A) & Ch. Matr. = St
<80 12 00 0E 24 03> // FM/AM-Prescale = 24
,
hex
FM-Matrix = Sound A Mono
<80 12 00 10 00 5A> // NICAM-Prescale = 5A
hex
<80 10 00 20 00 01> // Standard Select:
Automatic Standard Detection
// Wait till STANDARD RESULT contains a value ≤ 07FF
// IF STANDARD RESULT contains 0000
// do some error handling
// ELSE
<80 12 00 00 73 00> // Main Volume 0 dB
3.5.6. Software Flow for
Interrupt driven STATUS Check
A detailed software flow diagram is shown in Fig. 3–2
on page 36.
If the D_CTR_I/O_1 pin of the MSP 44x8G is con-
nected to an interrupt input pin of the controller, the fol-
lowing interrupt handler can be applied to be automati-
cally called with each status change of the
MSP 44x8G. The interrupt handler may adjust the dis-
play according to the new status information.
Interrupt Handler:
<80 11 02 00 <81 dd dd> // Read STATUS
// adjust display with given status information
// Return from Interrupt
Micronas
35