MSP 34x0G  
DATA SHEET  
6.5.5. NICAM Deemphasis  
6.6. Manual/Compatibility Mode:  
Description of DSP Read Registers  
A J17 Deemphasis is always applied to the NICAM  
signal. It is not switchable.  
All readable registers are 16-bit wide. Transmissions  
via I2C bus have to take place in 16-bit words. Some of  
the defined 16-bit words are divided into low and high  
byte, thus holding two different control entities.  
6.5.6. Identification Mode for A2 Stereo Systems  
These registers are not writable.  
Identification Mode  
00 15hex  
L
Standard B/G  
(German Stereo)  
0000 0000  
RESET  
00hex  
6.6.1. Stereo Detection Register  
for A2 Stereo Systems  
Standard M  
(Korean Stereo)  
0000 0001  
0011 1111  
01hex  
3Fhex  
Stereo Detection  
Register  
00 18hex  
H
Reset of Ident-Filter  
Stereo Mode  
Reading  
(two’s complement)  
To shorten the response time of the identification algo-  
rithm after a program change between two FM-Stereo  
capable programs, the reset of the ident-filter can be  
applied.  
MONO  
near zero  
STEREO  
positive value (ideal  
reception: 7Fhex  
)
Sequence:  
BILINGUAL  
negative value (ideal  
reception: 80hex)  
1. Program change  
2. Reset ident-filter  
3. Set identification mode back to standard B/G or M  
4. Wait approx. 500 ms  
Note: It is no longer necessary to read out and evalu-  
ate the A2 identification level. All evaluation is  
performed in the MSP and indicated in the STA-  
TUS register.  
5. Read stereo detection register  
Note: This register is initialized during STANDARD  
SELECTION and is automatically updated when  
Auto-matic Sound Select (MODUS[0]=1) is on.  
6.6.2. DC Level Register  
DC Level Readout  
FM1 (MSP-Ch2)  
00 1Bhex  
00 1Chex  
H+L  
H+L  
6.5.7. FM DC Notch  
DC Level Readout  
FM2 (MSP-Ch1)  
The DC compensation filter (FM DC Notch) for FM  
input can be switched off. This is used to speed up the  
automatic search function (see Section 6.4.7.). In nor-  
mal FM-mode, the FM DC Notch should be switched  
on.  
DC Level  
[8000hex ... 7FFFhex]  
values are 16 bit two’s  
complement  
The DC level register measures the DC component of  
the incoming FM signals (FM1 and FM2). This can be  
used for seek functions in satellite receivers and for IF  
FM frequencies fine tuning. A too low demodulation  
frequency (DCO) results in a positive DC-level and  
vice versa. For further processing, the DC content of  
the demodulated FM signals is suppressed. The time  
constant τ, defining the transition time of the DC Level  
Register, is approximately 28 ms.  
FM DC Notch  
00 17hex  
L
ON  
0000 0000  
Reset  
00hex  
OFF  
0011 1111  
3Fhex  
100  
May 27, 2003; 6251-476-1DS  