HAL880
DATA SHEET
3.5. Recommended Operating Conditions
Functional operation of the device beyond those indicated in the “Recommended Operating Conditions/Characteris-
tics” is not implied and may result in unpredictable behavior, reduce reliability and lifetime of the device.
All voltages listed are referenced to ground (GND).
Symbol
VDD
IOUT
RL
Parameter
Pin No.
Min.
4.5
Typ.
5
Max.
5.5
1
Unit
V
Supply Voltage
1
3
3
3
Continuous Output Current
Load Resistor
−1
−
mA
kΩ
nF
5.0
10
10
−
CL
Load Capacitance
0.33
1000
RL: Can be pull-up or pull-down resistor
3.5.1. Storage and Shelf Life
The permissible storage time (shelf life) of the sensors is unlimited, provided the sensors are stored at a maximum of
30 °C and a maximum of 85% relative humidity. At these conditions, no Dry Pack is required.
Solderability is guaranteed for one year from the date code on the package.
18
Feb. 23, 2009; DSH000152_001EN
Micronas