DATA SHEET  
HAL855  
2.3. Calibration Procedure  
2.3.1. General Procedure  
Step 2: Initialize DSP  
As the DIGITAL OUTPUT register value depends on  
the settings of SLOPE, SHIFT and the OUTPUT  
CHARACTERISTIC, these registers have to be initial-  
ized with defined values, first:  
For calibration in the system environment, the applica-  
tion kit from Micronas is recommended. It contains the  
hardware for the generation of the serial telegram for  
programming (Programmer Board Version 5.1) and the  
corresponding software (PC85x) for the input of the  
register values.  
– ShiftINITIAL = 50%  
– OUTPUT CHARACTERISTIC = ’Linear Standard’  
(Setpoint 0 = 0, Setpoint 1 = 16, Setpoint 2 = 32, ...,  
Setpoint 31 = 496).  
For the individual calibration of each sensor in the cus-  
tomer application, a two-point adjustment is recom-  
mended (see Fig. 2–5 on page 14 for an example).  
The calibration shall be done as follows:  
– SlopeINITIAL depends on the setting of the digital  
low-pass filter (see Table 2–8).  
Table 2–8: Initial slope values  
Step 1: Input of the registers which need not be  
adjusted individually  
3 dB Frequency  
SlopeINITIAL  
0.2578  
80  
The magnetic circuit, the magnetic material with its  
temperature characteristics, the filter frequency, the  
part number and the output format are given for this  
application.  
160  
500  
1000  
2000  
0.2578  
0.1938  
Therefore, the values of the following registers should  
be identical for all sensors of the customer application.  
0.1938  
0.3398  
– FILTER  
(according to the maximum signal frequency)  
– RANGE  
Step 3: Define Calibration Points  
(according to the maximum magnetic field at the  
sensor position)  
For highest accuracy of the sensor, calibration points  
near the minimum and maximum input signal are rec-  
ommended.  
– TC and TCSQ  
(depends on the material of the magnet and the  
other temperature dependencies of the application)  
Define nominal values DOUT1NOM and DOUT2NOM of  
the DIGITAL OUTPUT register at the calibration points  
1 and 2, respectively.  
– OUTPUT FORMAT  
(according to the application requirements)  
– OUTPUT PERIOD  
(according to the application requirements)  
Note: Micronas software PC85x uses default settings  
– PARTNUMBER  
DOUT1NOM = 0 and DOUT2NOM = 3968.  
(in case Biphase-M output format is used)  
The output is clamped to Setpoint 0 and  
Setpoint 31. In the case of “Linear Standard’”,  
– OFFSET CORRECTION  
– SLEW RATE  
Setpoint 0  
corresponds  
to  
DIGITAL  
OUTPUT = 0, while Setpoint 31 corresponds to  
DIGITAL OUTPUT = 3968.  
Write the appropriate settings into the HAL855 regis-  
ters.  
Micronas  
Nov. 26, 2008; DSH000149_003EN  