HAL82x
DATA SHEET
3.8. Power-On Operation
at TJ = −40 °C to +170 °C, after programming and locking. Typical Characteristics for TJ = 25 °C.
Symbol
PORUP
Parameter
Min.
Typ.
3.4
Max.
Unit
V
Power-On Reset Voltage (UP)
Power-On Reset Voltage (DOWN)
−
−
−
−
PORDOWN
3.0
V
3.9. Overvoltage and Undervoltage Detection
at TJ = −40 °C to +170 °C, Typical Characteristics for TJ = 25 °C, after programming and locking
Symbol
Parameter
Pin No.
Min.
−
Typ.
4.2
Max.
4.3
Unit
V
Test Conditions
1)
V
V
Undervoltage Detection Level
Overvoltage Detection Level
1
1
DD,UV
DD,OV
1)
8.5
8.9
10.0
V
1)
If the supply voltage drops below V
or rises above V
, the output voltage is switched to V (≥97% of V at R = 10 kΩ to GND).
DD,OV DD DD L
DD,UV
The CLAMP-LOW register has to be set to a voltage ≥ 200 mV.
Note: The over- and undervoltage detection is activated only after locking the sensor!
3.10. Magnetic Characteristics
at TJ = −40 °C to +170 °C, VDD = 4.5 V to 5.5 V, GND = 0 V after programming and locking,
at Recommended Operation Conditions if not otherwise specified in the column “Conditions”.
Typical Characteristics for TJ = 25 °C and VDD = 5 V.
Symbol
Parameter
Pin No.
Min.
Typ.
Max.
Unit
Test Conditions
B = 0 mT, I = 0 mA, T = 25 °C,
3
−0.5
0
0.5
mT
B
Magnetic Offset
OUT
J
Offset
unadjusted sensor
−10
0
10
μT/K
B = 0 mT, I = 0 mA
ΔB
/ΔT
Magnetic Offset Change
OUT
Offset
due to T
J
22
Feb. 3, 2009; DSH000143_003EN
Micronas