ADVANCE INFORMATION  
HAL815  
Step 2: Calculation of VOQ and Sensitivity  
3. Specifications  
3.1. Outline Dimensions  
±0.1  
There are two ways to calculate the values for VOQ  
and Sensitivity.  
sensitive area  
0.4  
1.5  
4.06  
Manual Calculation:  
0.3  
y
Set the system to calibration point 1 (angle 1 = 25°)  
and read the register ADC-READOUT. For our exam-  
ple, the result is ADC-READOUT1 = 2500.  
±0.1  
4.05  
0.48  
0.55  
Next, set the system to calibration point 2 (angle 2 =  
25°), and read the register ADC-READOUT again. For  
our example, the result is ADC-READOUT2 = +2350.  
1
2
3
0.36  
13.0  
min.  
With these measurements and the targets VOUT1  
4.5 V and VOUT2 = 0.5 V, the values for Sensitivity and  
VOQ are calculated as  
=
0.42  
1.27 1.27  
(2.54)  
4.5 V 0.5 V  
2500 2350  
2048  
5 V  
Sensitivity =  
= 0.3378  
*
2500 * (−0.3378) * 5 V  
V
= 4.5 V −  
= 2.438 V  
branded side  
OQ  
2048  
45°  
0.8  
Software Calibration:  
SPGS0014-3-A/2E  
Use the menu CALIBRATE from the PC software and  
enter the values 4.5 V for VOUT1 and 0.5 V for VOUT2  
Fig. 3–1:  
.
Plastic Transistor Single Outline Package  
(TO-92UT)  
Weight approximately 0.14 g  
Dimensions in mm  
Set the system to calibration point 1 (angle 1 = 25°),  
hit the button “Read ADC-Readout1”, set the system to  
calibration point 2 (angle 2 = 25°), hit the button “Read  
ADC-Readout2”, and hit the button “Calculate”. The  
software will then calculate the appropriate VOQ and  
Sensitivity.  
Note: A mechanical tolerance of ±50 µm applies to all  
dimensions where no tolerance is explicitly given.  
This calculation has to be done individually for each  
sensor. Now, write the calculated values with the “write  
and store” command into the HAL 815 for program-  
ming the sensor.  
3.2. Dimensions of Sensitive Area  
0.25 mm x 0.25 mm  
Step 3: Locking the Sensor  
3.3. Position of Sensitive Area  
The last step is activating the LOCK function with the  
“LOCK” command. The sensor is now locked and does  
not respond to any programming or reading com-  
mands.  
TO-92UT  
center of the package  
y = 1.5 mm nominal  
Warning: This register cannot be reset!  
Micronas  