DATA SHEET  
HAL574  
4.2. HAL574  
Applications  
The HAL574 is a medium sensitive unipolar switching  
sensor (see Fig. 4–5).  
The HAL574 is designed for applications with one  
magnetic polarity and weak magnetic amplitudes at  
the sensor position such as:  
The sensor turns to high current consumption with the  
magnetic south pole on the branded side of the pack-  
age and turns to low current consumption if the mag-  
netic field is removed. It does not respond to the mag-  
netic north pole on the branded side.  
– applications with large airgap or weak magnets,  
– solid state switches,  
– contactless solutions to replace micro switches,  
– position and end point detection, and  
– rotating speed measurement.  
For correct functioning in the application, the sensor  
requires only the magnetic south pole on the branded  
side of the package.  
Current consumption  
IDDhigh  
In this two-wire sensor family, the HAL584 is a sensor  
with the same magnetic characteristics but with an  
inverted output characteristic.  
BHYS  
Magnetic Features:  
IDDlow  
– switching type: unipolar  
– medium sensitivity  
0
BOFF  
BON  
B
– typical BON: 9.2 mT at room temperature  
– typical BOFF: 7.2 mT at room temperature  
Fig. 4–5: Definition of magnetic switching points for  
the HAL574  
– typical temperature coefficient of magnetic switching  
points is 0 ppm/K  
– operates with static magnetic fields and dynamic  
magnetic fields up to 10 kHz  
Magnetic Characteristics at TJ = 40 °C to +140 °C, VDD = 4.3 V to 24 V,  
Typical Characteristics for VDD = 12 V  
Magnetic flux density values of switching points.  
Positive flux density values refer to the magnetic south pole at the branded side of the package.  
Parameter  
On point B  
Typ.  
9.2  
Off point B  
Typ.  
7.2  
Hysteresis B  
HYS  
Magnetic Offset  
Unit  
ON  
OFF  
T
Min.  
5.5  
5.5  
5.5  
5
Max.  
12  
Min.  
5
Max.  
Min.  
Typ.  
2
Max.  
Min.  
Typ.  
8.2  
8.2  
8.2  
8.2  
Max.  
J
40 °C  
25 °C  
11.5  
11.5  
11.5  
11.5  
0.5  
0.5  
0.5  
0.2  
3
mT  
mT  
mT  
mT  
9.2  
12  
5
7.2  
2
3
100 °C  
140 °C  
9.2  
12  
5
7.2  
2
3
8.8  
12.5  
3.5  
7.5  
1.9  
3.5  
The hysteresis is the difference between the switching points BHYS = BON BOFF  
The magnetic offset is the mean value of the switching points BOFFSET = (BON + BOFF) / 2  