HAL560
4.2. HAL560
Applications
TheHAL560isalowsensitiveunipolarswitchingsensor
with an inverted output (see Fig. 4–5).
The HAL560 is designed for applications with one mag-
neticpolarityandstrongmagneticamplitudesatthesen-
sor position where an inverted output signal is required
such as:
The sensor turns to low current consumption with the
magnetic south pole on the branded side of the package
and turns to high current consumption if the magnetic
field is removed. It does not respond to the magnetic
north pole on the branded side.
– applications with strong magnets,
– solid state switches,
– contactless solutions to replace micro switches,
– position and end point detection, and
– rotating speed measurement.
For correct functioning in the application, the sensor re-
quires only the magnetic south pole on the branded side
of the package.
Magnetic Features:
Current consumption
– switching type: unipolar inverted
– low sensitivity
I
DDhigh
B
HYS
– typical B : 45.6 mT at room temperature
ON
– typical B
: 51.7 mT at room temperature
OFF
I
DDlow
– operates with static magnetic fields and dynamic mag-
netic fields up to 10 kHz
0
B
ON
B
OFF
B
Fig. 4–5: Definition of magnetic switching points for
the HAL560
Magnetic Characteristics at T = –40 °C to +170 °C, V = 4 V to 24 V,
J
DD
Typical Characteristics for V = 12 V
DD
Magnetic flux density values of switching points.
Positive flux density values refer to the magnetic south pole at the branded side of the package.
Parameter
On point B
Typ.
Off point B
Hysteresis B
HYS
Magnetic Offset
Unit
ON
OFF
T
J
Min.
41
Max.
52
Min.
Typ.
Max.
Min.
Typ.
6.5
6
Max.
Min.
Typ.
49.8
49.5
48.4
47.3
46.6
Max.
–40 °C
46.5
46.5
45.7
44.8
44.2
47
53
59
4
3
2
2
2
10
9
mT
mT
mT
mT
mT
25 °C
100 °C
140 °C
170 °C
41
52
46
52.5
51.1
49.8
49
58.5
57.5
56.5
55.5
41
52
45
5.4
5
8
39
51
43.5
42
8
38
50
4.8
8
The hysteresis is the difference between the switching points B
= B
– B
OFF ON
HYS
The magnetic offset is the mean value of the switching points B
= (B + B
) / 2
OFF
OFFSET
ON
Changes to the previous edition:
– tighter specification for B
at –40 °C, 25 °C, and 100 °C
OFF
– specification for 140 °C and 170 °C added
14
Micronas