DATA SHEET  
HAL542  
4. Type Description  
4.1. HAL542  
Applications  
The HAL542 is the optimal sensor for applications with  
alternating magnetic signals and weak magnetic  
amplitude at the sensor position such as:  
The HAL542 is the most sensitive latching sensor of  
this family (see Fig. 4–1).  
– applications with large air gap or weak magnets,  
– rotating speed measurement,  
The output turns low with the magnetic south pole on  
the branded side of the package and turns high with  
the magnetic north pole on the branded side. The out-  
put does not change if the magnetic field is removed.  
For changing the output state, the opposite magnetic  
field polarity must be applied.  
– commutation of brushless DC motors, and  
– CAM shaft sensors, and  
– magnetic encoders.  
For correct functioning in the application, the sensor  
requires both magnetic polarities (north and south) on  
the branded side of the package.  
Output Voltage  
VO  
BHYS  
Magnetic Features:  
– switching type: latching  
VOL  
– high sensitivity  
B
BOFF  
0
BON  
– typical BON: 2.6 mT at room temperature  
– typical BOFF: 2.6 mT at room temperature  
Fig. 4–1: Definition of magnetic switching points for  
the HAL542  
– operates with static magnetic fields and dynamic  
magnetic fields up to 10 kHz  
– typical temperature coefficient of magnetic switching  
points is 1000 ppm/K  
Magnetic Characteristics at TJ = 40 °C to +140 °C, VDD = 4.3 V to 24 V,  
Typical Characteristics for VDD = 12 V  
Magnetic flux density values of switching points.  
Positive flux density values refer to the magnetic south pole at the branded side of the package.  
Parameter  
On point B  
Typ.  
2.8  
Off point B  
Typ.  
Hysteresis B  
HYS  
Magnetic Offset  
Unit  
ON  
OFF  
T
Min.  
1
Max.  
5
Min.  
5  
Max.  
Min.  
Typ.  
5.85  
5.5  
Max.  
Min.  
Typ.  
Max.  
J
40 °C  
25 °C  
2.8  
1  
4.5  
4.5  
3.7  
3.3  
7.2  
6.5  
6.3  
6.2  
0
0
0
0
mT  
mT  
mT  
mT  
1
2.6  
4.5  
4.4  
4.6  
4.5  
4.4  
4.6  
2.6  
1  
1.5  
1.5  
100 °C  
140 °C  
0.95  
0.6  
2.5  
2.5  
0.95  
0.6  
5.0  
2.4  
2.4  
4.8  
The hysteresis is the difference between the switching points BHYS = BON BOFF  
The magnetic offset is the mean value of the switching points BOFFSET = (BON + BOFF) / 2  