欢迎访问ic37.com |
会员登录 免费注册
发布采购

HAL516SF-A 参数 Datasheet PDF下载

HAL516SF-A图片预览
型号: HAL516SF-A
PDF下载: 下载PDF文件 查看货源
内容描述: 霍尔效应传感器系列 [Hall-Effect Sensor Family]
分类和应用: 传感器换能器
文件页数/大小: 48 页 / 1632 K
品牌: MICRONAS [ MICRONAS ]
 浏览型号HAL516SF-A的Datasheet PDF文件第20页浏览型号HAL516SF-A的Datasheet PDF文件第21页浏览型号HAL516SF-A的Datasheet PDF文件第22页浏览型号HAL516SF-A的Datasheet PDF文件第23页浏览型号HAL516SF-A的Datasheet PDF文件第25页浏览型号HAL516SF-A的Datasheet PDF文件第26页浏览型号HAL516SF-A的Datasheet PDF文件第27页浏览型号HAL516SF-A的Datasheet PDF文件第28页  
HAL 502  
DATA SHEET  
4.2. HAL 502  
Applications  
The HAL 502 is the most sensitive latching sensor of  
this family (see Fig. 4–5).  
The HAL 502 is the optimal sensor for all applications  
with alternating magnetic signals and weak magnetic  
amplitude at the sensor position such as:  
The output turns low with the magnetic south pole on  
the branded side of the package and turns high with  
the magnetic north pole on the branded side. The out-  
put does not change if the magnetic field is removed.  
For changing the output state, the opposite magnetic  
field polarity must be applied.  
– applications with large air gap or weak magnets,  
– rotating speed measurement,  
– commutation of brushless DC motors,  
– CAM shaft sensors, and  
– magnetic encoders.  
For correct functioning in the application, the sensor  
requires both magnetic polarities (north and south) on  
the branded side of the package.  
Output Voltage  
VO  
Magnetic Features:  
– switching type: latching  
BHYS  
– high sensitivity  
– typical BON: 2.6 mT at room temperature  
– typical BOFF: 2.6 mT at room temperature  
VOL  
B
BOFF  
0
BON  
– operates with static magnetic fields and dynamic  
magnetic fields up to 10 kHz  
Fig. 4–5: Definition of magnetic switching points for  
– typical temperature coefficient of magnetic switching  
the HAL 502  
points is 1000 ppm/K  
Magnetic Characteristics at TJ = 40 °C to +170 °C, VDD = 3.8 V to 24 V,  
Typical Characteristics for VDD = 12 V  
Magnetic flux density values of switching points.  
Positive flux density values refer to the magnetic south pole at the branded side of the package.  
Parameter  
On point B  
Typ.  
2.8  
Off point B  
Typ.  
Hysteresis B  
HYS  
Magnetic Offset  
Unit  
ON  
OFF  
T
Min.  
1
Max.  
5
Min.  
5  
Max.  
Min.  
Typ.  
5.6  
5.2  
4.8  
4.6  
Max.  
Min.  
Typ.  
Max.  
J
40 °C  
25 °C  
2.8  
1  
4.5  
4.5  
3.7  
3.5  
7.2  
7
0
0
0
0
mT  
mT  
mT  
mT  
1
2.6  
4.5  
4.3  
4.3  
4.5  
4.3  
4.3  
2.6  
1  
1.5  
1.5  
140 °C  
170 °C  
0.9  
0.9  
2.4  
2.4  
0.9  
0.9  
6.8  
6.8  
2.3  
2.3  
The hysteresis is the difference between the switching points BHYS = BON BOFF  
The magnetic offset is the mean value of the switching points BOFFSET = (BON + BOFF) / 2  
24  
Jan. 11. 2010; DSH000020_004EN  
Micronas