HAL 501  
DATA SHEET  
4. Type Description  
4.1. HAL 501  
Applications  
The HAL 501 is the optimal sensor for applications  
with alternating magnetic signals and weak magnetic  
amplitude at the sensor position such as:  
The HAL 501 is the most sensitive sensor of this family  
with bipolar switching behavior (see Fig. 4.1.).  
– applications with large air gap or weak magnets,  
– rotating speed measurement,  
The output turns low with the magnetic south pole on  
the branded side of the package and turns high with  
the magnetic north pole on the branded side. The out-  
put state is not defined for all sensors if the magnetic  
field is removed again. Some sensors will change the  
output state and some sensors will not.  
– commutation of brushless DC motors, and  
– CAM shaft sensors, and  
– magnetic encoders.  
For correct functioning in the application, the sensor  
requires both magnetic polarities (north and south) on  
the branded side of the package.  
Output Voltage  
VO  
BHYS  
Magnetic Features:  
– switching type: bipolar  
VOL  
– very high sensitivity  
BOFF  
0
BON  
B
– typical BON: 0.5 mT at room temperature  
– typical BOFF: 0.7 mT at room temperature  
Fig. 4–1: Definition of magnetic switching points for  
HAL 501  
– operates with static magnetic fields and dynamic  
magnetic fields up to 10 kHz  
Magnetic Characteristics at TJ = 40 °C to +170 °C, VDD = 3.8 V to 24 V,  
Typical Characteristics for VDD = 12 V  
Magnetic flux density values of switching points.  
Positive flux density values refer to the magnetic south pole at the branded side of the package.  
Parameter  
On point B  
Typ.  
0.6  
Off point B  
Typ.  
Hysteresis B  
Magnetic Offset B  
Unit  
ON  
OFF  
HYS  
OFFSET  
T
Min.  
0.8  
0.5  
1.2  
1.5  
Max.  
2.5  
2.3  
2.8  
3
Min.  
2.5  
2.3  
2.5  
2.5  
Max.  
Min.  
Typ.  
1.4  
1.2  
1.1  
0.9  
Max.  
Min.  
Typ.  
0.1  
0.1  
0
Max.  
J
40 °C  
25 °C  
0.8  
0.8  
0.5  
1.3  
2
0.5  
0.5  
0.5  
0.4  
2
mT  
mT  
mT  
mT  
0.5  
0.7  
1.9  
1.8  
1.8  
1.4  
1.4  
140 °C  
170 °C  
0.6  
0.5  
0.7  
0.2  
0.2  
The hysteresis is the difference between the switching points BHYS = BON BOFF  
The magnetic offset is the mean value of the switching points BOFFSET = (BON + BOFF) / 2  
22  
Jan. 11. 2010; DSH000020_004EN  
Micronas