DATA SHEET
HAL 502
mT
6
HAL 502
mT
6
HAL 502
BONmax
BON
BOFF
BON
BOFF
4
2
4
BON
BONtyp
2
0
BONmin
VDD = 3.8 V
TA = −40 °C
A = 25 °C
T
0
VDD = 4.5 ... 24 V
TA = 100 °C
TA = 170 °C
BOFFmax
−2
−4
−6
−2
−4
BOFFtyp
BOFF
BOFFmin
−6
0
−50
0
50
100
150
TA, TJ
200 °C
5
10
15
20
25
VDD
30 V
Fig. 4–6: Typ. magnetic switching points
Fig. 4–8: Magnetic switching points
versus supply voltage
versus temperature
Note: In the diagram “Magnetic switching points ver-
sus temperature” the curves for:
mT
6
HAL 502
B
ONmin, BONmax, BOFFmin, and BOFFmax
refer to junction temperature, whereas typical
curves refer to ambient temperature.
BON
BOFF
4
2
BON
TA = −40 °C
TA = 25 °C
TA = 100 °C
TA = 170 °C
0
−2
−4
−6
BOFF
3.0
3.5
4.0
4.5
5.0
5.5
6.0 V
V
DD
Fig. 4–7: Typ. magnetic switching points
versus supply voltage
Micronas
Jan. 11. 2010; DSH000020_004EN
25