HAL300
DATA SHEET
3.2. Dimensions of Sensitive Area
0.08 mm x 0.17 mm
3.3. Positions of Sensitive Areas (nominal values)
SOT89B-2
TO92UA-3/-4
x = −1.025 mm
1
x = 1.025 mm
2
x − x = 2.05 mm
1
2
y = 0.95 mm
y = 1.0 mm
Bd = 0.2 mm
3.4. Absolute Maximum Ratings
Stresses beyond those listed in the “Absolute Maximum Ratings” may cause permanent damage to the device. This
is a stress rating only. Functional operation of the device at these conditions is not implied. Exposure to absolute maxi-
mum rating conditions for extended periods will affect device reliability.
This device contains circuitry to protect the inputs and outputs against damage due to high static voltages or electric
fields; however, it is advised that normal precautions be taken to avoid application of any voltage higher than absolute
maximum-rated voltages to this high-impedance circuit.
All voltages listed are referenced to ground (GND).
Symbol
Parameter
Pin No.
Limit Values
Max.
Unit
Min.
–15
–0.3
–
1)
V
V
Supply Voltage
1
3
3
28
28
30
V
DD
1)
Output Voltage
V
O
I
O
Continuous Output On Current
Junction Temperature Range
mA
°C
T
–40
–40
150
170
J
2)
1)
2)
as long as T max is not exceeded
t < 1000h
J
3.4.1. Storage and Shelf Life
The permissible storage time (shelf life) of the sensors is unlimited, provided the sensors are stored at a maximum of
30 °C and a maximum of 85% relative humidity. At these conditions, no Dry Pack is required.
Solderability is guaranteed for one year from the date code on the package.
12