HAL300
Magnetic Characteristics at T = –40 °C to +170 °C, V = 4.5 V to 24 V
J
DD
Typical Characteristics for V = 12 V
DD
Magnetic flux density values of switching points (Condition: –10 mT < B < 10 mT)
0
Positive flux density values refer to the magnetic south pole at the branded side ot the package. ∆B = B – B
S1
S2
Parameter
–40 °C
25 °C
100 °C
170 °C
Unit
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
On point ∆B
0.2
1.2
–1.0
2.2
2.2
0
1.2
–1.0
2.2
2.2
–0.5
1.0
–1.1
2.1
2.5
–2.0
0.5
–1.2
1.7
3.0
mT
mT
mT
mT
ON
∆B > ∆B
ON
Off point ∆B
–2.2
1.2
–0.2
3.0
–2.2
1.2
0
–2.5
1.0
0.5
3.0
1.5
–3.0
0.8
2.0
3.0
2.5
OFF
∆B < ∆B
OFF
Hysteresis
∆B = ∆B – ∆B
OFF
3.0
1.1
HYS
ON
Offset ∆B
=
–1.1
0.1
1.1
–1.1
0.1
–1.5
–0.1
–2.5
–0.5
OFFSET
(∆B + ∆B
)/2
OFF
ON
5.0
Output Voltage
2.0
V
OH
V
OL
2.0
DB
DB
0
DB
DB
ON max
OFF min
OFF
ON
1.0
DB
HYS
∆B = B – B
S1
S2
Fig. 7: Recommended pad size SOT-89A
Dimensions in mm
Fig. 6: Definition of switching points and hysteresis
Micronas
7