HAL 300, HAL 320
Data Sheet Supplement
Subject:
Improvement of SOT-89B Package
Data Sheet Concerned:
HAL 300, 6251-345-1DS, Edition July 15, 1998
HAL 320, 6251-439-1DS, Edition July 15, 1998
Supplement:
Edition:
No. 1/ 6251-532-1DSS
July 4, 2000
Changes:
– position tolerance of the sensitive area reduced
– tolerances of the outline dimensions reduced
– thickness of the leadframe changed to 0.15 mm (old 0.125 mm)
– HAL 300 now available in SOT-89B
– SOT-89A will be discontinued in December 2000
4.55
1.7
sensitive area S
1
2
0.2
sensitive area S
0.2
0.15
0.3
2
2
y
±0.2
4
2.55
x
x
2
1
min.
0.25
top view
1
3
0.4
0.4
1.15
0.4
3.0
1.5
branded side
±0.04
0.06
SPGS0022-5-B3/1E
Position of sensitive area
HAL 300
HAL 320
x1+x2
x1= x2
y
(2.05±0.001) mm
(2.25±0.001) mm
1.125 mm nominal
0.95 mm nominal
1.025 mm nominal
0.95 mm nominal
Note: A mechanical tolerance of ±0.05 mm applies to all dimensions where no tolerance is explicitly given.
Position tolerances of the sensitive areas are defined in the package diagram.
Micronas