DC and AC parameters
M58BW016DT, M58BW016DB, M58BW016FT, M58BW016FB
7
DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics tables that
follow, are derived from tests performed under the measurement conditions summarized in
Table 13: Operating and AC measurement conditions. Designers should check that the
operating conditions in their circuit match the measurement conditions when relying on the
quoted parameters.
Table 13. Operating and AC measurement conditions
Value
Parameter
Units
Min
Max
Supply voltage (V
)
2.7
2.4
3.6
V
V
DD
Input/output supply voltage (V
)
V
DD
DDQ
Grade 6
Grade 3
–40
–40
90
°C
°C
pF
ns
ns
V
Ambient temperature (T )
A
125
Load capacitance (C )
30
L
Clock rise and fall times
Input rise and fall times
Input pulses voltages
4
4
0 to V
DDQ
Input and output timing ref. voltages
V
/2
V
DDQ
Figure 6.
AC measurement input/output waveform
V
DDQ
V
DDQIN
V
/2
/2
DDQ
V
DDQIN
0 V
AI04153
1.
V
= V
.
DD
DDQ
38/70