 浏览型号M25PX16-VMW6TG的Datasheet PDF文件第27页浏览型号M25PX16-VMW6TG的Datasheet PDF文件第28页浏览型号M25PX16-VMW6TG的Datasheet PDF文件第29页浏览型号M25PX16-VMW6TG的Datasheet PDF文件第30页浏览型号M25PX16-VMW6TG的Datasheet PDF文件第32页浏览型号M25PX16-VMW6TG的Datasheet PDF文件第33页浏览型号M25PX16-VMW6TG的Datasheet PDF文件第34页浏览型号M25PX16-VMW6TG的Datasheet PDF文件第35页  
M25PX16 Serial Flash Embedded Memory  
PAGE PROGRAM  
PAGE PROGRAM  
The PAGE PROGRAM command allows bytes in the memory to be programmed, which  
means the bits are changed from 1 to 0. Before a PAGE PROGRAM command can be ac-  
cepted a WRITE ENABLE command must be executed. After the WRITE ENABLE com-  
mand has been decoded, the device sets the write enable latch (WEL) bit.  
The PAGE PROGRAM command is entered by driving chip select (S#) LOW, followed by  
the command code, three address bytes, and at least one data byte on serial data input  
(DQ0).  
If the eight least significant address bits (A7-A0) are not all zero, all transmitted data that  
goes beyond the end of the current page are programmed from the start address of the  
same page; that is, from the address whose eight least significant bits (A7-A0) are all  
zero. S# must be driven LOW for the entire duration of the sequence.  
If more than 256 bytes are sent to the device, previously latched data are discarded and  
the last 256 data bytes are guaranteed to be programmed correctly within the same  
page. If less than 256 data bytes are sent to device, they are correctly programmed at the  
requested addresses without any effects on the other bytes of the same page.  
For optimized timings, it is recommended to use the PAGE PROGRAM command to  
program all consecutive targeted bytes in a single sequence rather than to use several  
PAGE PROGRAM sequences, each containing only a few bytes.  
S# must be driven HIGH after the eighth bit of the last data byte has been latched in.  
Otherwise the PAGE PROGRAM command is not executed.  
As soon as S# is driven HIGH, the self-timed PAGE PROGRAM cycle is initiated; the cy-  
cles's duration is tPP. While the PAGE PROGRAM cycle is in progress, the status register  
may be read to check the value of the write in progress (WIP) bit. The WIP bit is 1 during  
the self-timed PAGE PROGRAM cycle, and 0 when the cycle is completed. At some un-  
specified time before the cycle is completed, the write enable latch (WEL) bit is reset.  
A PAGE PROGRAM command is not executed if it applies to a page protected by the  
block protect bits BP2, BP1, and BP0.  
Figure 19: PAGE PROGRAM Command Sequence  
0
7
8
C
x
C
LSB  
A[MIN]  
LSB  
D
D
D
D
D
D
D
D
D
IN  
DQ[0]  
Command  
IN  
IN  
IN  
IN  
IN  
IN  
IN  
IN  
MSB  
A[MAX]  
MSB  
1. Cx = 7 + (A[MAX] + 1).  
Note:  