 浏览型号JS28F00AM29EWLA的Datasheet PDF文件第36页浏览型号JS28F00AM29EWLA的Datasheet PDF文件第37页浏览型号JS28F00AM29EWLA的Datasheet PDF文件第38页浏览型号JS28F00AM29EWLA的Datasheet PDF文件第39页浏览型号JS28F00AM29EWLA的Datasheet PDF文件第41页浏览型号JS28F00AM29EWLA的Datasheet PDF文件第42页浏览型号JS28F00AM29EWLA的Datasheet PDF文件第43页浏览型号JS28F00AM29EWLA的Datasheet PDF文件第44页  
256Mb, 512Mb, 1Gb, 2Gb: 3V Embedded Parallel NOR Flash  
Protection Operations  
Protection Operations  
Blocks can be protected individually against accidental PROGRAM, ERASE, or READ op-  
erations on both 8-bit and 16-bit configurations. The block protection scheme is shown  
in the Software Protection Scheme figure.  
Memory block and extended memory block protection is configured through the lock  
register (see Lock Register section).  
LOCK REGISTER Commands  
After the ENTER LOCK REGISTER COMMAND SET (40h) command has been issued, all  
bus READ or PROGRAM operations can be issued to the lock register.  
The PROGRAM LOCK REGISTER (A0h) command allows the lock register to be config-  
ured. The programmed data can then be checked with a READ LOCK REGISTER com-  
mand by driving CE# and OE# LOW with the appropriate address data on the address  
bus.  
PASSWORD PROTECTION Commands  
After the ENTER PASSWORD PROTECTION COMMAND SET (60h) command has been  
issued, the commands related to password protection mode can be issued to the device.  
The PROGRAM PASSWORD (A0h) command is used to program the 64-bit password  
used in the password protection mode. To program the 64-bit password, the complete  
command sequence must be entered eight times at eight consecutive addresses selec-  
ted by A[1:0] plus DQ15/A-1 in 8-bit mode, or four times at four consecutive addresses  
selected by A[1:0] in 16-bit mode. By default, all password bits are set to 1. The password  
can be checked by issuing a READ PASSWORD command.  
Note: To use the password protection feature on the 2Gb device, the password must be  
programmed to both upper die and lower die.  
The READ PASSWORD command is used to verify the password used in password pro-  
tection mode. To verify the 64-bit password, the complete command sequence must be  
entered eight times at eight consecutive addresses selected by A[1:0] plus DQ15/A-1 in  
8-bit mode, or four times at four consecutive addresses selected by A[1:0] in 16-bit  
mode. If the password mode lock bit is programmed and the user attempts to read the  
password, the device will output FFh onto the I/O data bus.  
The UNLOCK PASSWORD (25/03h) command is used to clear the nonvolatile protec-  
tion bit lock bit, allowing the nonvolatile protection bits to be modified. The UNLOCK  
PASSWORD command must be issued, along with the correct password, and requires a  
1μs delay between successive UNLOCK PASSWORD commands in order to prevent  
hackers from cracking the password by trying all possible 64-bit combinations. If this  
delay does not occur, the latest command will be ignored. Approximately 1μs is required  
for unlocking the device after the valid 64-bit password has been provided.  
NONVOLATILE PROTECTION Commands  
After the ENTER NONVOLATILE PROTECTION COMMAND SET (C0h) command has  
been issued, the commands related to nonvolatile protection mode can be issued to the  
device.  
PDF: 09005aef849b4b09  