 浏览型号JR28F032M29EWLA的Datasheet PDF文件第49页浏览型号JR28F032M29EWLA的Datasheet PDF文件第50页浏览型号JR28F032M29EWLA的Datasheet PDF文件第51页浏览型号JR28F032M29EWLA的Datasheet PDF文件第52页浏览型号JR28F032M29EWLA的Datasheet PDF文件第54页浏览型号JR28F032M29EWLA的Datasheet PDF文件第55页浏览型号JR28F032M29EWLA的Datasheet PDF文件第56页浏览型号JR28F032M29EWLA的Datasheet PDF文件第57页  
32Mb, 64Mb, 128Mb: 3V Embedded Parallel NOR Flash  
Protection Operations  
NONVOLATILE PROTECTION BIT LOCK BIT Commands  
After the ENTER NONVOLATILE PROTECTION BIT LOCK BIT COMMAND SET (50h)  
command has been issued, the commands that allow the nonvolatile protection bit lock  
bit to be set can be issued to the device.  
The PROGRAM NONVOLATILE PROTECTION BIT LOCK BIT (A0h) command is used to  
set the nonvolatile protection bit lock bit to 0, thus locking the nonvolatile protection  
bits and preventing them from being modified.  
The READ NONVOLATILE PROTECTION BIT LOCK BIT STATUS command is used to  
read the status of the nonvolatile protection bit lock bit.  
VOLATILE PROTECTION Commands  
After the ENTER VOLATILE PROTECTION COMMAND SET (E0h) command has been  
issued, commands related to the volatile protection mode can be issued to the device.  
The PROGRAM VOLATILE PROTECTION BIT (A0h) command individually sets a vola-  
tile protection bit to 0 for a given block. If the nonvolatile protection bit for the same  
block is set, the block is locked regardless of the value of the volatile protection bit. (See  
the Block Protection Status table.)  
The status of a volatile protection bit for a given block can be read by issuing a READ  
VOLATILE PROTECTION BIT STATUS command along with the block address.  
The CLEAR VOLATILE PROTECTION BIT (A0h) command individually clears (sets to 1)  
the volatile protection bit for a given block. If the nonvolatile protection bit for the same  
block is set, the block is locked regardless of the value of the volatile protection bit. (See  
the Block Protection Status table.)  
EXTENDED MEMORY BLOCK Commands  
The device has one extra 128-word extended memory block that can be accessed only  
by the ENTER EXTENDED MEMORY BLOCK (88h) command. The extended memory  
block is 128 words (x16) or 256 bytes (x8). It is used as a security block to provide a per-  
manent 128-bit security identification number or to store additional information. The  
device can be shipped with the extended memory block prelocked permanently by Mi-  
cron, including the 128-bit security identification number. Or, the device can be ship-  
ped with the extended memory block unlocked, enabling customers to permanently  
program and lock it. (See Lock Register, the AUTO SELECT command, and the Block  
Protection table.)  
Table 21: Extended Memory Block Address and Data  
Address  
x16  
Data  
x8  
Micron prelocked  
Customer Lockable  
000000h–00000Fh 000000h–000007h  
000010h–0000FFh 000008h–00007Fh  
Secure ID number  
Determined by customer  
Secure ID number  
Determined by customer  
Protected and  
unavailable  
After the ENTER EXTENDED MEMORY BLOCK command has been issued, the device  
enters the extended memory block mode. All bus READ or PROGRAM operations are  
conducted on the extended memory block, and the extended memory block is ad-  
PDF: 09005aef84dc44a7  