WRA-YQD-20&WRB-YQD-20W Series  
20W, WIDE INPUT, ISOLATED & REGULATED DUAL/SINGLE OUTPUT DC-DC CONVERTER  
SELECTION GUIDE  
Input voltage range  
(VDC)  
Output voltage  
(VDC)  
Output current  
max.(mA)  
Order code  
Efficiency typ.(%)  
WRA1205YQD-20W  
WRA1212YQD-20W  
WRA1215YQD-20W  
WRA1224YQD-20W  
WRA2405YQD-20W  
WRA2412YQD-20W  
WRA2415YQD-20W  
WRA2424YQD-20W  
WRA4805YQD-20W  
WRA4812YQD-20W  
WRA4815YQD-20W  
WRA4824YQD-20W  
WRB1205YQD-20W  
WRB1212YQD-20W  
WRB1215YQD-20W  
WRB1224YQD-20W  
WRB2405YQD-20W  
WRB2412YQD-20W  
WRB2415YQD-20W  
WRB2424YQD-20W  
WRB4805YQD-20W  
WRB4812YQD-20W  
WRB4815YQD-20W  
WRB4824YQD-20W  
9~18  
9~18  
±5  
±12  
±15  
±24  
±5  
±12  
±15  
±24  
±5  
±12  
±15  
±24  
5
±2000  
±833  
±667  
±417  
±2000  
±833  
±667  
±417  
±2000  
±833  
±667  
±417  
4000  
1667  
1333  
833  
78  
82  
80  
83  
79  
82  
83  
78  
80  
84  
85  
78  
79  
80  
80  
78  
82  
82  
83  
78  
80  
84  
85  
79  
9~18  
9~18  
FEATURES  
18~36  
18~36  
18~36  
18~36  
36~72  
36~72  
36~72  
36~72  
9~18  
Wide 2:1 DC input range  
In/out capacitance1000pF  
Protections : Short circuit / Overload / Over voltage  
1500VDC I/O isolation for D/D  
Cooling by free air convection  
Built-in remote ON-OFF control  
100% full load burn-in test  
Fixed switching frequency at 225KHz  
Lost cost  
9~18  
12  
9~18  
15  
9~18  
24  
18~36  
18~36  
18~36  
18~36  
36~72  
36~72  
36~72  
36~72  
5
4000  
1667  
1333  
833  
12  
15  
24  
MTBF>1000Khours  
5
4000  
1667  
1333  
833  
High reliability  
12  
15  
3 year warranty  
24  
MODEL SELECTION  
WRB 24 12 Y QD -20W(1667)  
Product Series Input Voltage  
Output Voltage Wide (2:1) Input Range  
2"×2"DIP Package Style  
SPECIFICATION  
Ripple&Noise(max.)  
(Note.2)  
100mVp-p  
±0.5%  
Rated Power(Output current)  
OUTPUT  
Line Regulation  
Load Regulation  
(Note.3)  
(Note.4)  
±0.5%  
Above 105% rated output power  
APPLICATIONS  
Overload  
Protection type : Over power limiting, recovers automatically after fault  
condition is removed  
The WRA(B)-YQD-20W Series of DC/DC  
converters has been designed for a wide range of  
applications including communications, industrial  
systems and battery powered mobile equipments.  
Key features are high power density and 2:1 wide  
input ranges of 18~36 VDC and 36~72 VDC.(But  
also can do high power density and 4:1 ultrawide  
input ranges of 9~36 VDC and 18~72 VDC.)  
XX03 :3.8~4.95V  
XX12:13.8 ~ 18V  
XX05 :5.75 ~ 7.5V  
PROTECTION  
Over Voltage  
XX15:17.25 ~ 22.5V  
Protection type : Shut off o/p voltage, clamping by zener diode  
Protection type : Constant current limiting, recovers automatically after  
fault condition is removed  
Short Circuit  
Logic "1" or open: power on  
FUNCTION  
ON/OFF Control  
Logic "0" short to Vin-: power off  
Working Temp.  
-25~+85(Refer to output load derating curve)  
ENVIRONMENT  
Storage Temp.,Humidity  
Temp. Coefficient  
-25~+85, 0~95% RH  
±0.03%/ ℃(0~50℃)  
Design refer to LVD  
Safety Standards  
Isolation Voltage  
Isolation Resistance  
SAFETY&EMC  
(Note 5)  
I/P-O/P:1.5KVDC  
I/P-O/P:100M Ohms/500VDC  
MTBF  
322.4K hrs min.  
MIL-HDBK-217F (25)  
OTHERS  
Dimension  
Packing  
50.8×50.8×16mm (2"×2"×0.63") (L×W×H)  
110g;150pcs/15.8Kg/0.97CUFT  
MICRODC RESERVES THE COPYRIGHT  
1. All parameters are specified at normal input, rated load, 2570% RH ambient.  
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted  
pair-wire terminated with a 0.1uf & 47uf parallel capacitor.  
NOTE  
3.Line regulation is measured from low line to high line at rated load.  
4.Load regulation is measured from 10% to 100%rated load  
5. Please prevent the converter from operating in overload or short circuit condition for  
more than 30 seconds.  
http://www.microdc.cn  
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646  
Page 1 of 3