General Specifications  
Physical Specifications  
Operating  
40 ... + 85 ℃  
+100 max.  
Case material  
steel, Nickel plated  
non conductive FR4  
epoxy (UL 94V-0 rated)  
14 g (0.55 oz)  
Temperature ranges  
Case temperature  
Storage  
Baseplate material  
Potting material  
Weight  
55 ... + 125 ℃  
Derating  
3.5% /K above 70 ℃  
95 % rel H max.  
>1 Mio. h @ + 25 ℃  
1500 VDC  
Humidity(non condensing)  
Soldering temperature  
max. 265 °C / 10 sec.  
Reliability, calculated MTBF (MIL-HDBK-217 E)  
Isolation voltage  
Input/Output  
Isolation capacity  
Isolation resistance  
Switching frequency  
Input/Output  
380 pF typ.  
Input/Output (500 VDC)  
> 1000 M Ohm  
300 kHz typ. (Pulse frequency modulation PFM)  
UL 60950, IEC 60950, EN 60950  
Safety standards  
Safety approval  
Compliance up to 60 VDC input voltage(SELV limit)  
UL /cUL File E188913 (5Vin models pending)  
TYPICAL CHARACTERISTICS  
APPLICATION NOTE  
Temperature Derating Graph  
Requirement on output load  
In order to ensure the product operate efficiently and reliably,in addition to a  
max load(namely full load), a minimum load is specified for this kind of  
DC/DC converter.Make sure the specified range of input voltage is not  
exceeded,the minimum output load no less than 10% load.If the actual  
load is less than the specified minimum load, the output ripple may increase  
sharply while its efficiency and reliability will reduce greatly.If the actual  
output power is very small,please add an appropriate resistor as extra  
loading,or contact our company for other lower output power products.  
Recommended Circuit  
RECOMMENDED CIRCUIT  
All the WRA_YD-5W&WRB_YD-5W Series have been tested according to  
the following recommended testing circuit before leaving factory.This series  
should be tested under load(See figure 1).  
Output Graph  
If you want to further decrease the input/output ripple,you can increase  
capacitance properly or choose capacitors with low ESR. However, the  
capacitance of the output filter capacitor must be proper. If the capacitance  
is too big, a startup problem might arise. For every channel of output,  
provided the safe and reliable operation is ensured, the greatest capacitance  
of its filter capacitor sees (Table 1).  
General:  
Cin: 5V12V 100μF  
24V48V 100μF-47μF  
Cout: 10μF/100mA  
Input current  
While using unstable power source,please ensure the output voltage and  
ripple voltage do not exceed indexes of the converter. Input current of  
power supply should afford the startup current of this kind of DC/DC module  
(See figure 2).  
General:Ip≤1.4*Iin-max  
No parallel connection or plug and play  
http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646  